Objectives: Our objectives were to evaluate the effectiveness of humanoid robot-based distraction on reducing distress and pain in children undergoing intravenous insertion.

Methods: A two-arm, open-label randomized controlled trial was conducted April 2017-May 2018, in a pediatric emergency department (ED). A sample of 86 children aged 6-11 years who required intravenous insertion were recruited. Exclusion criteria included hearing/visual impairments, neurocognitive delay, sensory impairment to pain, previous enrollment, and ED clinical staff discretion. Outcome measures included the Observed Scale of Behavioral Distress-Revised (OSBD-R) (distress) and the Faces Pain Scale-Revised (FPS-R) (pain).

Results: Of the 86 children recruited (median age 9 years, IQR 7,10); 55% (47/86) were male, 9% (7/82) were premature, 82% (67/82) had a previous ED visit, 31% (25/82) had a previous hospitalization and 78% (64/82) had previous intravenous insertion. Ninety-six percent (78/81) received topical anesthetic prior to intravenous insertion. Total OSBD-R distress score was 1.49 ± 2.36 (standard care) versus 0.78 ± 1.32 (robot) (p < 0.05). FPS-R pain score was 4 (IQR 2,6) (standard care) versus 2 (IQR 0,4) (robot) (p = 0.13). Parental anxiety immediately after the procedure was 36.7 (11.1) (standard care) versus 31.3 (8.5) (robot) (p = 0.04). Parents were more satisfied with pain management in the robotic distraction group (95% vs 72% very satisfied) (p = 0.002).

Conclusions: Humanoid robot-based distraction therapy is associated with a modest positive impact on child distress for pediatric intravenous insertion, but not pain. It can be considered a potential tool in the ED toolkit for procedural pain-associated distress reduction.

Clinical Trial Registration: Clinicaltrials.gov Identifier: NCT02997631.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s43678-020-00023-5DOI Listing

Publication Analysis

Top Keywords

intravenous insertion
16
robot-based distraction
8
distress pain
8
emergency department
8
osbd-r distress
8
intravenous
5
randomized trial
4
trial robot-based
4
distraction reduce
4
reduce children's
4

Similar Publications

PET has become an important clinical modality but is limited to imaging positron emitters. Recently, PET imaging withZr, which has a half-life of 3 days, has attracted much attention in immuno-PET to visualize immune cells and cancer cells by targeting specific antibodies on the cell surface. However,Zr emits a single gamma ray at 909 keV four times more frequently than positrons, causing image quality degradation in conventional PET.

View Article and Find Full Text PDF

Transjugular transcatheter edge-to-edge mitral valve repair in a patient with functional mitral regurgitation: a case report.

Eur Heart J Case Rep

January 2025

Department of Cardiovascular Medicine, Sendai Kousei Hospital, 1-20 Tsutsumidori-amamiya, Aoba Ward, Sendai, Miyagi 9810914, Japan.

Background: Transcatheter edge-to-edge mitral valve repair (M-TEER) using the MitraClip system is primarily performed using the transfemoral approach. However, when this approach is not feasible, the transjugular approach can be used as an alternative.

Case Summary: A 57-year-old man presented with heart failure and persistent New York Heart Association class IV symptoms, refractory to guideline-directed medical therapy, intravenous therapy, and intra-aortic balloon pumping.

View Article and Find Full Text PDF

Foreign body insertion into the urethra is uncommonly encountered in urology practice. Such insertion can result in a myriad of problems including bleeding, infectious sequelae, urinary retention, urethral injury or rupture, and resultant urethral stricture formation. This article describes a case in which an elderly male inserted a pencil into his urethra, which subsequently became lodged and required removal under regional anesthesia in the operating theater.

View Article and Find Full Text PDF

Background: Outpatient parenteral antibiotic therapy (OPAT) enhances patient safety, improves outcomes, and reduces healthcare costs by decreasing 30-day readmissions and adverse events. However, the optimal structure and follow-up protocols for OPAT programs remain undefined. Identifying high-risk patients for readmission and managing adverse drug events (ADEs) are critical components of OPAT care.

View Article and Find Full Text PDF

How to undertake peripheral intravenous cannulation.

Nurs Stand

December 2024

School of Nursing, Midwifery and Social Work, School of Health and Society, University of Salford, Salford, England.

Peripheral intravenous (IV) cannulation in adults is one of the most commonly performed healthcare procedures. It involves the insertion of a small tube into a vein using a needle, enabling the administration of fluids, blood products and nutrition, and the collection of blood samples. Healthcare professionals performing this procedure must undergo training to be able to undertake it effectively and safely.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!