Iris-claw lenses have gained increasing popularity over the last years and are by many surgeons regarded as viable options in eyes with insufficient capsular or zonular support. The iris-claw lens has two haptics with fine fissures for folding (enclavating) the mid-peripheral part of the iris stroma and can either be placed in front of or posterior to the iris. In particular, the retropupillary implantation has been increasingly chosen probably due to having an anatomical position similar to that of the crystalline lens. The present review is based on a literature review and also on the authors' clinical experience with this lens, and it focuses on surgical techniques and outcomes especially related to the characteristics of this lens, having haptics with claws that fixate the lens to the posterior iris. Implanting retropupillary iris-claw lenses has a relatively short learning curve, and there are only few complications reported during surgery. Retropupillary iris-claw lenses have demonstrated generally favourable efficiency and safety. However, the outcomes are probably more influenced by the reason for surgery and eye comorbidity than the lens itself. Albeit seldom reported, the postoperative complications have mostly been related to atrophy of the iris at the site of the haptics, or IOL decentration or disenclavation of one of the haptics. To date, however, there are few randomized clinical trials comparing this lens to other lens alternatives in eyes exhibiting insufficient capsular or zonular support for placing the lens in the ciliary sulcus. In the future, prospective studies with large samples should be performed to gain insights into the long-term safety of retropupillary placed iris-claw lenses, and for comparisons with the various other techniques of lens fixation.

Download full-text PDF

Source
http://dx.doi.org/10.1111/aos.14824DOI Listing

Publication Analysis

Top Keywords

iris-claw lenses
20
retropupillary iris-claw
16
lens
10
insufficient capsular
8
capsular zonular
8
zonular support
8
lens haptics
8
posterior iris
8
iris-claw
6
lenses
5

Similar Publications

Purpose: To compare the aberrometric profile of the Artisan Aphakia lens (Opthec BV) and transscleral plug FIL-SSF lens (Soleko) and to assess the impact of tilt and decentration on their optical performance.

Methods: This retrospective observational study was conducted at Azienda Ospedaliera Universitaria Careggi, Florence, Italy, with a consecutive cohort of aphakic eyes undergoing secondary lens implantation with an Artisan or FIL-SSF lens. Wavefront analysis was performed using a pyramidal wavefront-based aberrometer (Osiris-T; CSO).

View Article and Find Full Text PDF

: To compare the clinical outcome of suture and sutureless iris fixation techniques for dislocated intraocular lenses (IOLs). : Retrospective cohort study including patients who underwent surgery for late IOL dislocation over a 10-year period. IOL repositioning was achieved either by suturing the original IOL to the iris using the Siepser slipknot technique or by replacing it with a retropupillary sutureless iris claw IOL.

View Article and Find Full Text PDF

Purpose: To compare the refractive outcomes and the complications of implantation surgery by the Carlevale IOL to the Artisan iris-claw IOL.

Methods: Retrospective comparative study of consecutive surgical cases between 2019 and 2021 in our tertiary centre in Paris, France.

Results: We included 142 eyes in the Artisan group and 63 in the Carlevale group.

View Article and Find Full Text PDF

Purpose: This study aims to analyze the incidence of pseudophakic macular edema (PME) and the role of contributing risk factors following prepupillary or retropupillary implantation of iris-claw lenses.

Methods: This retrospective cohort study included patients who underwent iris-claw intraocular lens implantation over a 16-year period at the University Hospital of Santiago de Compostela, Spain. The presence of risk factors for PME was recorded, and surgical outcomes included visual acuity, macular OCT scans, and description of complications.

View Article and Find Full Text PDF

Lens drop and intraocular lens (IOL) drop can occur after cataract or phacoemulsification surgery, where the IOL is dislocated from the capsular bag into the vitreous cavity. The aim of this study was to investigate the short-term outcomes of implanting a retropupillary iris-claw in patients with IOL drop and lens drop after phacoemulsification. A cross-sectional study was conducted at Santosa Hospital, Bandung, West Java, Indonesia, from January 2020 to December 2023.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!