Leveraging Geometry to Enable High-Strength Continuum Robots.

Front Robot AI

Department Mechanical, Aerospace, and Biomedical Engineering, University of Tennessee - Knoxville, Knoxville, TN, United States.

Published: February 2021

Developing high-strength continuum robots can be challenging without compromising on the overall size of the robot, the complexity of design and the range of motion. In this work, we explore how the load capacity of continuum robots can drastically be improved through a combination of backbone design and convergent actuation path routing. We propose a rhombus-patterned backbone structure composed of thin walled-plates that can be easily fabricated via 3D printing and exhibits high shear and torsional stiffness while allowing bending. We then explore the effect of combined parallel and converging actuation path routing and its influence on continuum robot strength. Experimentally determined compliance matrices are generated for straight, translation and bending configurations for analysis and discussion. A robotic actuation platform is constructed to demonstrate the applicability of these design choices.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7930011PMC
http://dx.doi.org/10.3389/frobt.2021.629871DOI Listing

Publication Analysis

Top Keywords

continuum robots
12
high-strength continuum
8
actuation path
8
path routing
8
leveraging geometry
4
geometry enable
4
enable high-strength
4
continuum
4
robots developing
4
developing high-strength
4

Similar Publications

Small-scale continuum robots hold promise for interventional diagnosis and treatment, yet existing models struggle to achieve small size, precise steering, and visualized functional treatment simultaneously, termed an "impossible trinity". This study introduces an optical fiber-based continuum robot integrated imaging, high-precision motion, and multifunctional operation abilities at submillimeter-scale. With a slim profile of 0.

View Article and Find Full Text PDF

Neural Network-Based Shape Analysis and Control of Continuum Objects.

Biomimetics (Basel)

December 2024

School of Mechanical Engineering and Automation, Harbin Institute of Technology Shenzhen, Shenzhen 518055, China.

Soft robots are gaining increasing attention in current robotics research due to their continuum structure. However, accurately recognizing and reproducing the shape of such continuum robots remains a challenge. In this paper, we propose a novel approach that combines contour extraction with camera reconstruction to obtain shape features.

View Article and Find Full Text PDF

Carbon nanorings (CNRs) serve as an ideal quantum system for novel electronic and magnetic properties. Although extensive theoretical studies utilizing molecular dynamics (MD) simulations have investigated the formation and structural characteristics of CNRs, systematically analyzing their properties across various toric sizes remains challenging due to the inherent complexity of this system. In this study, we introduce a novel finite element method, the Chebyshev-Ritz method, as an alternative approach to investigating the structural properties of CNRs.

View Article and Find Full Text PDF

Tendon-driven continuum soft robots are currently applied in research and are given a promising perspective for future applications. For the routing of the tendons from the actuator to the point where the loading is demanded, two routing possibilities exist in the literature: internal routing of the tendons with the help of structurally embedded Bowden sheaths and external tendon routing where the tendon is not in contact with the soft structure. The application of the latter is a clear disadvantage for applications due to the high risk of interference with the tendon, for example, causing the tendon to break.

View Article and Find Full Text PDF

Comparison of Classical, Neural Network and Hybrid Models for Hysteretic Single-tendon Catheter Kinematics.

IEEE Robot Autom Lett

January 2025

Department of Cardiac Surgery, Boston Children's Hospital, Harvard Medical School, Boston, MA 02115, USA.

While robotic control of catheter motion can improve tip positioning accuracy, hysteresis arising from tendon friction and flexural deformation degrades kinematic modeling accuracy. In this paper, we compare the capabilities of three types of models for representing the forward and inverse kinematic maps of a clinical single-tendon cardiac catheter. Classical hysteresis models, neural networks and hybrid combinations of the two are included.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!