Anteromedial portal-guided femoral tunnel preparation during anterior cruciate ligament reconstruction can be difficult owing to poor visualization. This may cause iatrogenic damage to the medial femoral condyle cartilage and the posterior cruciate ligament fibers or overdrilling through the lateral femoral cortex, creating difficulties in the use of femoral suspensory devices during anterior cruciate ligament reconstruction. We describe an accurate and safe technique for femoral graft socket preparation using a cannulated, calibrated drill with an adjustable stop and slotted cannula. This easy and reproducible technique uses simple additional instruments and effectively addresses concerns related to femoral graft socket preparation, without requiring additional surgical time.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7917199 | PMC |
http://dx.doi.org/10.1016/j.eats.2020.10.026 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!