Background/purpose: Our study goals were to evaluate the diagnostic performance of four anti-SARS-CoV-2 antibodies tests and the differences in dynamic immune responses between COVID-19 patients with and without pneumonia.
Methods: We collected 184 serum samples from 70 consecutively qRT-PCR-confirmed COVID-19 patients at four participating hospitals from 23 January 2020 to 30 September 2020. COVID-19 pneumonia was defined as the presence of new pulmonary infiltration. Serum samples were grouped by the duration after symptom onset on a weekly basis for antibody testing and analysis. The four immunoassays: Beckman SARS-CoV-2 IgG/IgM (Beckman Test), Siemens (ADVIA Centaur®) SARS-CoV-2 Total (COV2T) (Siemens Test), SBC COVID-19 IgG ELISA (SBC Test) and EliA SARS-CoV-2-Sp1 IgG/IgM/IgA P2 Research (EliA Test) were used for detecting the SARS-CoV-2 specific antibodies.
Results: The sensitivity of all tests reached 100% after 42 days of symptom onset. Siemens Test, the only test detecting total anti-SARS-CoV-2 antibodies, had the best performance in the early diagnosis of COVID-19 infection (day 0-7: 77%; day 8-14: 95%) compared to the other 3 serological tests. All tests showed 100% specificity except SBC Test (98%). COVID-19 patients with pneumonia had significantly higher testing signal values than patients without pneumonia (all p values < 0.05, except EliA IgM Test). However, Siemens Test and SBC Test had highest probability in early prediction of the presence of COVID-19 pneumonia.
Conclusion: Chronological analysis of immune response among COVID-19 patients with different serological tests provides important information in the early diagnosis of SARS-CoV-2 infection and prediction of the risk of pneumonia after infection.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7900773 | PMC |
http://dx.doi.org/10.1016/j.jmii.2021.02.003 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!