A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Validity and reliability of the 'Isometric Exercise Scale' (IES) for measuring ratings of perceived exertion during continuous isometric exercise. | LitMetric

Isometric exercise (IE) interventions are an effective non-medical method of reducing arterial blood pressure (BP). Current methods of prescribing and controlling isometric exercise intensity often require the use of expensive equipment and specialist knowledge. However, ratings of perceived exertion (RPE) may provide a more accessible means of monitoring exercise intensity. Therefore, the aim of this study was to assess the validity of a specific Isometric Exercise Scale (IES) during a continuous incremental IE test. Twenty-nine male participants completed four incremental isometric wall squat tests. Each test consisted of five 2-min stages of progressively increasing workload. Workload was determined by knee joint angle from 135° to 95°. The tests were continuous with no rest periods between the stages. Throughout the exercise protocol, RPE (IES and Borg's CR-10), heart rate and blood pressure were recorded. A strong positive linear relationship was found between the IES and the CR-10 (r = 0.967). Likewise, strong positive relationships between the IES and wall squat duration (r = 0.849), HR (r = 0.819) and BP (r = 0.841) were seen. Intra-class correlation coefficients and coefficients of variations for the IES ranged from r = 0.81 to 0.91 and 4.5-54%, respectively, with greater reliability seen at the higher workloads. The IES provides valid and reliable measurements of RPE, exercise intensity, and the changes in physiological measures of exertion during continuous incremental IE; as such, the IES can be used as an accessible measure of exercise intensity during IE interventions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7970867PMC
http://dx.doi.org/10.1038/s41598-021-84803-8DOI Listing

Publication Analysis

Top Keywords

isometric exercise
16
exercise intensity
16
exercise
9
ies
8
ratings perceived
8
perceived exertion
8
exertion continuous
8
blood pressure
8
continuous incremental
8
wall squat
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!