Electrochemically based technologies are rapidly moving from the laboratory to bedside applications and wearable devices, like in the field of cardiovascular disease. Major efforts have focused on the biosensor component in contrast with those employed in creating more suitable detection algorithms for long-term real-world monitoring solutions. The calibration curve procedure presents major limitations in this context. The objective is to propose a new algorithm, compliant with current clinical guidelines, which can overcome these limitations and contribute to the development of trustworthy wearable or telemonitoring solutions for home-based care. A total of 123 samples of phosphate buffer solution were spiked with different concentrations of troponin, the gold standard method for the diagnosis of the acute coronary syndrome. These were classified as normal or abnormal according to established clinical cut-off values. Off-the-shelf screen-printed electrochemical sensors and cyclic voltammetry measurements (sweep between -1 and 1 V in a 5 mV step) was performed to characterize the changes on the surface of the biosensor and to measure the concentration of troponin in each sample. A logistic regression model was developed to accurately classify these samples as normal or abnormal. The model presents high predictive performance according to specificity (94%), sensitivity (92%), precision (92%), recall (92%), negative predictive value (94%) and F-score (92%). The area under the curve of the precision-recall curve is 97% and the positive and negative likelihood ratios are 16.38 and 0.082, respectively. Moreover, high discriminative power is observed from the discriminate odd ratio (201) and the Youden index (0.866) values. The promising performance of the proposed algorithm suggests its capability to overcome the limitations of the calibration curve procedure and therefore its suitability for the development of trustworthy home-based care solutions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7924205PMC
http://dx.doi.org/10.3390/bioengineering8020028DOI Listing

Publication Analysis

Top Keywords

acute coronary
8
coronary syndrome
8
calibration curve
8
curve procedure
8
overcome limitations
8
development trustworthy
8
home-based care
8
normal abnormal
8
development detection
4
detection algorithm
4

Similar Publications

Left atrial strain (LAS) was recently introduced as a parameter that reflects on left atrial function. Consequently, changes in LAS can inform the development of cardiovascular diseases, hence providing a window for non-invasive and cost-effective testing of these diseases and their complications at early stages of development, potentially offering a segway towards preventive interventions. LAS has yet to be implemented into standard practice.

View Article and Find Full Text PDF

Assessing modified HEART scores with high-sensitivity troponin for low-risk chest pain in the emergency department.

Intern Emerg Med

December 2024

Department of Emergency Medicine, JPS Health Network, 1500 S. Main St., Fort Worth, TX, 76104, USA.

The accuracy of using HEART (history, electrocardiogram, age, risk factors, and troponin) scores with high-sensitivity cardiac troponin (hs-cTn) to risk stratify emergency department (ED) chest pain patients remains uncertain. We aim to compare the performance accuracy of determining major adverse cardiac event (MACE) among three modified HEART (mHEART) scores with the use of hs-cTn to risk stratify ED chest pain patients. This retrospective single-center observational study included ED patients with suspected acute coronary syndrome who had HEAR scores calculated and at least one hs-cTnI result.

View Article and Find Full Text PDF

Background: Little is known about how younger and older hospitalized patients differ with respect to reasons for admission, comorbidities, diagnostics, treatment and intercurrent problems.

Objective: The aim of the study was to compare the previously named characteristics in the clinical profile of patients > 90 years old (nonagenarians) with a control group of patients 70-75 years old admitted to an emergency hospital department for internal medicine and cardiology.

Material And Method: The study included all consecutive nonagenarians and gender-matched control patients who were admitted during 2011.

View Article and Find Full Text PDF

Development of a Self-Deploying Extra-Aortic Compression Device for Medium-Term Hemodynamic Stabilization: A Feasibility Study.

Adv Sci (Weinh)

December 2024

Graduate School of Biomedical Engineering, Faculty of Engineering, and Tyree Institute of Health Engineering (IHealthE), UNSW Sydney, Kensington Campus, Sydney, NSW, 2052, Australia.

Hemodynamic stabilization is crucial in managing acute cardiac events, where compromised blood flow can lead to severe complications and increased mortality. Conditions like decompensated heart failure (HF) and cardiogenic shock require rapid and effective hemodynamic support. Current mechanical assistive devices, such as intra-aortic balloon pumps (IABP) and extracorporeal membrane oxygenation (ECMO), offer temporary stabilization but are limited to short-term use due to risks associated with prolonged blood contact.

View Article and Find Full Text PDF

Background: Lung transplantation is a viable lifesaving option for patients with diffuse pulmonary arteriovenous malformations (AVMs). We present a case of diffuse pulmonary AVMs associated with juvenile polyposis and hereditary hemorrhagic telangiectasia (JP-HHT) that was successfully managed by lung transplantation.

Case Presentation: A 19-year-old woman developed severe hypoxemia due to pulmonary AVMs diagnosed at 4 years of age.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!