Planar phase-variation microwave sensors have attracted increasing interest in recent years since they combine the advantages of planar technology (including low cost, low profile, and sensor integration with the associated circuitry for post-processing and communication purposes, among others) and the possibility of operation at a single frequency (thereby reducing the costs of the associated electronics). This paper reviews and compares three different strategies for sensitivity improvement in such phase-variation sensors (devoted to material characterization). The considered approaches include line elongation (through meandering), dispersion engineering (by considering slow-wave artificial transmission lines), and reflective-mode sensors based on step-impedance open-ended lines. It is shown that unprecedented sensitivities compatible with small sensing regions are achievable with the latter approach.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7926889PMC
http://dx.doi.org/10.3390/s21041542DOI Listing

Publication Analysis

Top Keywords

planar phase-variation
8
phase-variation microwave
8
microwave sensors
8
material characterization
8
sensors
4
sensors material
4
characterization review
4
review comparison
4
comparison approaches
4
approaches planar
4

Similar Publications

High-temperature reduction of TiO causes the gradual formation of structural defects, leading to oxygen vacancy planar defects and giving rise to Magnéli phases, which are substoichiometric titanium oxides that follow the formula Ti O, with 4 ≤ ≤ 9. A high concentration of defects provides several possible configurations for Ti and Ti within the crystal, with the variation in charge ordered states changing the electronic structure of the material. The changes in crystal and electronic structures of Magnéli phases introduce unique properties absent in TiO, facilitating their diverse applications.

View Article and Find Full Text PDF

Motion-Compensated Multishot Pancreatic Diffusion-Weighted Imaging With Deep Learning-Based Denoising.

Invest Radiol

January 2025

From the Department of Radiology, Stanford University, Stanford, CA (K.W., M.J.M., A.M.L., A.B.S., A.J.H., D.B.E., R.L.B.); Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (K.W.); GE HealthCare, Houston, TX (X.W.); GE HealthCare, Boston, MA (A.G.); and GE HealthCare, Menlo Park, CA (P.L.).

Objectives: Pancreatic diffusion-weighted imaging (DWI) has numerous clinical applications, but conventional single-shot methods suffer from off resonance-induced artifacts like distortion and blurring while cardiovascular motion-induced phase inconsistency leads to quantitative errors and signal loss, limiting its utility. Multishot DWI (msDWI) offers reduced image distortion and blurring relative to single-shot methods but increases sensitivity to motion artifacts. Motion-compensated diffusion-encoding gradients (MCGs) reduce motion artifacts and could improve motion robustness of msDWI but come with the cost of extended echo time, further reducing signal.

View Article and Find Full Text PDF

Can we reliably assess spine movement quality in clinics? A comparison of systems to evaluate movement reliability in a healthy population.

J Biomech

January 2025

School of Human Kinetics, Faculty of Health Sciences, University of Ottawa, 200 Lees Avenue, Ottawa, Ontario K1N 6N5, Canada; Ottawa-Carleton Institute for Biomedical Engineering, Ottawa, Ontario, Canada. Electronic address:

Inertial measurement units (IMUs) have the potential to facilitate a large influx of spine movement and motor control data to help stratify low back pain (LBP) diagnosis and care; however, uncertainties related to validity and equipment/movement reliability are preventing widespread use and acceptance. This study evaluated the concurrent validity of Xsens DOT IMUs relative to gold-standard optical motion capture equipment, and compared within- and between-day reliability of both systems to track spine range of motion (ROM) and movement quality (MQ) by evaluating intraclass correlation coefficients (ICC), standard error of measurement (SEM), coefficient of variation (CV), and minimum detectable difference (MDD). ROM was evaluated during planar ROM movements, and local dynamic stability (LDS; λ), mean absolute relative phase (MARP) and deviation phase (DP) were estimated from repetitive trunk flexion at 3 speeds, in 15 healthy controls to assess MQ.

View Article and Find Full Text PDF

Background: Quantitative real-time MRI-based temperature mapping techniques are hampered by abdominal motion. Intrascan motion can be reduced by rapid acquisition sequences such as 2D echo planar imaging (EPI), and inter-scan organ displacement can be compensated by image processing such as optical flow (OF) algorithms. However, motion field estimation can be seriously affected by local variation of signal intensity on magnitude images inherent to tissue heating, potentially leading to erroneous temperature estimates.

View Article and Find Full Text PDF

The interactions between fluid flow and structural components of collapsible tubes are representative of those in several physiological systems. Although extensively studied, there exists a lack of characterization of the three-dimensionality in the structural deformations of the tube and its influence on the flow field. This experimental study investigates the spatio-temporal relationship between 3D tube geometry and the downstream flow field under conditions of fully open, closed, and slamming-type oscillating regimes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!