Swine Small Intestine Sealing Performed by Different Vessel Sealing Devices: Ex-Vivo Test.

Vet Sci

Dipartimento dell'Emergenze e Trapianti di Organi (D.E.T.O.), Sezione di Cliniche Veterinarie e Produzioni Animali, Università degli Studi di Bari "Aldo Moro", 70124 Bari, Italy.

Published: February 2021

This study aimed to evaluate the sealing quality of swine small intestine using different laparoscopic radiofrequency vessel sealing devices (two 5 mm: RFVS-1 and -2; one 10 mm: RFVS-3) and a harmonic scalpel (HS) compared to golden standard closure technique. The study was divided into two arms. In study arm 1: n = 50 swine intestinal loops (10 per group) were transected with each instrument and the loops in which the devices provided complete sealing, at the gross inspection, were tested for maximum burst pressure (BP) and histological evaluation and compared to an automatic linear stapler. After the BP tests, the devices that achieved significantly lower BP values were excluded from the second arm. The RFVS-1 and -3 provided statistically significant results and were used in study arm 2, to obtain full-thickness biopsies along the antimesenteric border of the loop and were compared with hand-sewn intestinal closure (n = 30; 10 per group). The biopsies were histologically evaluated for thermal injury and diagnostic features, and intestinal loops tested for BP. RFVS-3 achieved comparable results (69.78 ± 4.23 mmHg, interquartile range (IQR) 5.8) to stapler closing technique (71.09 ± 4.22 mmHg, IQR 4.38; > 0.05), while the RFVS-1 resulted in significantly ( < 0.05) lower BP (45.28 ± 15.23 mmHg, IQR 24.95) but over the physiological range, conversely to RFVS-2 (20.16 ± 7.19 mmHg, IQR 12.02) and HS (not measurable). RFVS-3 resulted not significantly different ( > 0.05) (45.09 ± 8.75 mmHg, IQR 10.48) than Suture (35.71 ± 17.51 mmHg, IQR 23.77); RFVS-1 resulted significantly lower values (23.96 ± 10.63 mmHg, IQR 9.62; < 0.05). All biopsies were judged diagnostic. Data confirmed that RFVS-1 and -3 devices provided suitable intestinal sealing, with BP pressures over the physiological range. Conversely, the HS and RFVS-2 should not be considered for intestinal sealing. RFVS devices could be employed to obtain small intestine stump closure or full-thickness biopsies. However, further studies should be performed in live animals to assess the role of the healing process.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7926574PMC
http://dx.doi.org/10.3390/vetsci8020034DOI Listing

Publication Analysis

Top Keywords

mmhg iqr
24
small intestine
12
swine small
8
vessel sealing
8
sealing devices
8
study arm
8
intestinal loops
8
devices provided
8
lower values
8
full-thickness biopsies
8

Similar Publications

Objective: To determine if prestretching (PS) of the abdominal wall provided improved working space during elective laparoscopic procedures in dogs.

Study Design: Prospective cohort study.

Animals: Fifty client-owned dogs undergoing elective laparoscopic procedures.

View Article and Find Full Text PDF

Background: Sodium-glucose co-transporter-2 inhibitors (SGLT2i) are recommended for reducing the renal and cardiovascular risk in patients with chronic kidney disease (CKD) based on the positive results reported by clinical trials. However, real-world data on the efficacy and the safety of these drugs in CKD population followed in nephrology setting are lacking.

Methods: We report the effects of dapagliflozin in CKD patients by using data collected during a learning program in which 105 nephrologists added dapagliflozin (10 mg/day) to consecutive patients referred to their renal clinics.

View Article and Find Full Text PDF

Midterm Outcomes of Endovascular Pulmonary Artery Debanding in Children.

Catheter Cardiovasc Interv

January 2025

Department of Pediatric Cardiology, Hotel Dieu de France University Medical Center, Saint Joseph University, Beirut, Lebanon.

Background: Pulmonary artery banding (PAB) palliates pulmonary over-circulation, while endovascular debanding (ED) offers a less invasive alternative to repeat surgery.

Objectives: To evaluate our experience with ED.

Aims: Retrospective review of single-center data (2015-2023) on children with single, multiple, or "Swiss-cheese" muscular ventricular septal defects (MVSDs) undergoing ED.

View Article and Find Full Text PDF

Background: Our aim was to develop a quantitative model for immediately estimating the risk of death and/or brain injury in late-onset sepsis (LOS) in preterm infants, based on objective and measurable data available at the time sepsis is first suspected (i.e., time of blood culture collection).

View Article and Find Full Text PDF

Purpose: To report on in-vivo intrarenal pressure (IRP) during flexible ureteroscopy for treatment of kidney stones while using the novel flexible and navigable suction ureteral access sheath (FANS).