This study aimed to evaluate the sealing quality of swine small intestine using different laparoscopic radiofrequency vessel sealing devices (two 5 mm: RFVS-1 and -2; one 10 mm: RFVS-3) and a harmonic scalpel (HS) compared to golden standard closure technique. The study was divided into two arms. In study arm 1: n = 50 swine intestinal loops (10 per group) were transected with each instrument and the loops in which the devices provided complete sealing, at the gross inspection, were tested for maximum burst pressure (BP) and histological evaluation and compared to an automatic linear stapler. After the BP tests, the devices that achieved significantly lower BP values were excluded from the second arm. The RFVS-1 and -3 provided statistically significant results and were used in study arm 2, to obtain full-thickness biopsies along the antimesenteric border of the loop and were compared with hand-sewn intestinal closure (n = 30; 10 per group). The biopsies were histologically evaluated for thermal injury and diagnostic features, and intestinal loops tested for BP. RFVS-3 achieved comparable results (69.78 ± 4.23 mmHg, interquartile range (IQR) 5.8) to stapler closing technique (71.09 ± 4.22 mmHg, IQR 4.38; > 0.05), while the RFVS-1 resulted in significantly ( < 0.05) lower BP (45.28 ± 15.23 mmHg, IQR 24.95) but over the physiological range, conversely to RFVS-2 (20.16 ± 7.19 mmHg, IQR 12.02) and HS (not measurable). RFVS-3 resulted not significantly different ( > 0.05) (45.09 ± 8.75 mmHg, IQR 10.48) than Suture (35.71 ± 17.51 mmHg, IQR 23.77); RFVS-1 resulted significantly lower values (23.96 ± 10.63 mmHg, IQR 9.62; < 0.05). All biopsies were judged diagnostic. Data confirmed that RFVS-1 and -3 devices provided suitable intestinal sealing, with BP pressures over the physiological range. Conversely, the HS and RFVS-2 should not be considered for intestinal sealing. RFVS devices could be employed to obtain small intestine stump closure or full-thickness biopsies. However, further studies should be performed in live animals to assess the role of the healing process.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7926574 | PMC |
http://dx.doi.org/10.3390/vetsci8020034 | DOI Listing |
Vet Surg
January 2025
Department of Clinical Sciences, Cornell University Hospital for Animals, Ithaca, New York, USA.
Objective: To determine if prestretching (PS) of the abdominal wall provided improved working space during elective laparoscopic procedures in dogs.
Study Design: Prospective cohort study.
Animals: Fifty client-owned dogs undergoing elective laparoscopic procedures.
Clin Kidney J
January 2025
Nephrology and Dialysis Unit, Department of Advanced Medical and Surgical Sciences, University of Campania, Naples, Italy.
Background: Sodium-glucose co-transporter-2 inhibitors (SGLT2i) are recommended for reducing the renal and cardiovascular risk in patients with chronic kidney disease (CKD) based on the positive results reported by clinical trials. However, real-world data on the efficacy and the safety of these drugs in CKD population followed in nephrology setting are lacking.
Methods: We report the effects of dapagliflozin in CKD patients by using data collected during a learning program in which 105 nephrologists added dapagliflozin (10 mg/day) to consecutive patients referred to their renal clinics.
Catheter Cardiovasc Interv
January 2025
Department of Pediatric Cardiology, Hotel Dieu de France University Medical Center, Saint Joseph University, Beirut, Lebanon.
Background: Pulmonary artery banding (PAB) palliates pulmonary over-circulation, while endovascular debanding (ED) offers a less invasive alternative to repeat surgery.
Objectives: To evaluate our experience with ED.
Aims: Retrospective review of single-center data (2015-2023) on children with single, multiple, or "Swiss-cheese" muscular ventricular septal defects (MVSDs) undergoing ED.
Pediatr Res
January 2025
Neonatal Intensive Care Unit, University Hospital of Modena, Via del Pozzo, 41124, Modena, Italy.
Background: Our aim was to develop a quantitative model for immediately estimating the risk of death and/or brain injury in late-onset sepsis (LOS) in preterm infants, based on objective and measurable data available at the time sepsis is first suspected (i.e., time of blood culture collection).
View Article and Find Full Text PDFWorld J Urol
January 2025
Division of Urology, University of Montreal Hospital Center, Montreal, Canada.
Purpose: To report on in-vivo intrarenal pressure (IRP) during flexible ureteroscopy for treatment of kidney stones while using the novel flexible and navigable suction ureteral access sheath (FANS).
Methods: A retrospective observational analysis was performed for 25 patients undergoing routine flexible ureteroscopy for treatment of renal stones between February 2024 and June 2024 from two centres in Canada. The LithoVue Elite™ ureteroscope (Boston Scientific Corp.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!