A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Efficacy and Safety of Dual-Frequency Ultrasound for Improving Skin Hydration and Erythema in Patients with Rosacea and Acne. | LitMetric

Inflammatory skin diseases, such as rosacea and acne, are major causes of facial erythema and accompanying skin barrier dysfunction. Several methods to restore the impaired skin barrier and improve facial erythema, such as medication, radiofrequency, laser, and ultrasound therapy were attempted. This study evaluated the efficacy and safety of dual-frequency ultrasound with impulse mode, for improving skin hydration and erythema in Asian subjects with rosacea and acne. Twenty-six subjects with facial erythema received an ultrasound treatment once per week, for 4 weeks, over both cheeks. The erythema index and transepidermal water loss (TEWL) were measured at each visit. Clinicians assessed the erythema improvement and patients evaluated their satisfaction level. The average decrease in TEWL and erythema index at 6 weeks was 5.37 ± 13.22 g·h·m ( = 0.020) and 39.73 ± 44.21 ( = 0.010), respectively. The clinician's erythema assessment and the subject satisfaction questionnaire score significantly improved at final follow-up ( < 0.001; = 0.003, respectively). No serious adverse effects were observed during the treatment and follow-up periods. The dual-frequency ultrasound with impulse mode appears to be effective and safe for improving skin hydration and erythema in patients with rosacea and acne.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7922048PMC
http://dx.doi.org/10.3390/jcm10040834DOI Listing

Publication Analysis

Top Keywords

rosacea acne
16
dual-frequency ultrasound
12
improving skin
12
skin hydration
12
hydration erythema
12
facial erythema
12
erythema
10
efficacy safety
8
safety dual-frequency
8
erythema patients
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!