A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Accuracy of Dynamic Computer-Assisted Implant Placement: A Systematic Review and Meta-Analysis of Clinical and In Vitro Studies. | LitMetric

Accuracy of Dynamic Computer-Assisted Implant Placement: A Systematic Review and Meta-Analysis of Clinical and In Vitro Studies.

J Clin Med

Center of Dental, Oral and Maxillofacial Medicine, Clinic for Dental Prosthetics, Ulm University, 89081 Ulm, Germany.

Published: February 2021

The aim of this systematic review and meta-analysis is to analyze the accuracy of implant placement using computer-assisted dynamic navigation procedures. An electronic literature search was carried out, supplemented by a manual search. The literature search was completed in June 2020. The results of in vitro and clinical studies were recorded separately from each other. For inclusion in the review, the studies had to examine at least the prosthetically relevant parameters for angle deviation, as well as global deviation or lateral deviation at the platform of the implant. Sixteen of 320 articles were included in the investigation: nine in vitro and seven clinical studies. The meta-analysis showed values of 4.1° for the clinical studies (95% CI, 3.12-5.10) and 3.7° for the in vitro studies (95% CI, 2.31-5.10) in terms of the angle deviation. The global deviation at the implant apex of the implant was 1.00 mm for the clinical studies (95% CI, 0.83-1.16) and 0.91 mm for the in vitro studies (95% CI, 0.60-1.12). These values indicate no significant difference between the clinical and in vitro studies. The results of this systematic review show a clinical accuracy of dynamic computer-assisted navigation that is comparable to that of static navigation. However, the dynamic navigation systems show a great heterogeneity that must be taken into account. Moreover, currently there are few clinical data available. Therefore, further investigations into the practicability of dynamic navigation seem necessary.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7916851PMC
http://dx.doi.org/10.3390/jcm10040704DOI Listing

Publication Analysis

Top Keywords

vitro studies
16
clinical studies
16
studies 95%
16
systematic review
12
dynamic navigation
12
studies
9
accuracy dynamic
8
dynamic computer-assisted
8
implant placement
8
review meta-analysis
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!