Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 144
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1002
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3142
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
En bloc spinal tumor resections are technically demanding procedures with high morbidity because of the conventionally large exposure area and aggressive resection goals. Stereotactic surgical navigation presents an opportunity to perform the smallest possible resection plan while still achieving an en bloc resection. Augmented reality (AR)-mediated spine surgery (ARMSS) via a mounted display with an integrated tracking camera is a novel FDA-approved technology for intraoperative "heads up" neuronavigation, with the proposed advantages of increased precision, workflow efficiency, and cost-effectiveness. As surgical experience and capability with this technology grow, the potential for more technically demanding surgical applications arises. Here, the authors describe the use of ARMSS for guidance in a unique osteotomy execution to achieve an en bloc wide marginal resection of an L1 chordoma through a posterior-only approach while avoiding a tumor capsule breach. A technique is described to simultaneously visualize the navigational guidance provided by the contralateral surgeon's tracked pointer and the progress of the BoneScalpel aligned in parallel with the tracked instrument, providing maximum precision and safety. The procedure was completed by reconstruction performed with a quad-rod and cabled fibular strut allograft construct, and the patient did well postoperatively. Finally, the authors review the technical aspects of the approach, as well as the applications and limitations of this new technology.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3171/2020.9.SPINE201219 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!