Alternative and Safe Technique to Tie Down a Biologic Aortic Valve in Small Aortic Roots.

Ann Thorac Surg

Department of Cardiac Surgery, St Bartholomew's Hospital, London, United Kingdom. Electronic address:

Published: August 2021

Biologic aortic valves are constructed with 3 stents corresponding to the commissures, which sit in the aortic root. When implanted using interrupted sutures, these stents may make the valve difficult to tie down safely in patients with small, calcified aortic roots. We present an easily reproducible technique to make this valve tie down safer.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.athoracsur.2020.12.091DOI Listing

Publication Analysis

Top Keywords

biologic aortic
8
aortic roots
8
aortic
5
alternative safe
4
safe technique
4
technique tie
4
tie biologic
4
aortic valve
4
valve small
4
small aortic
4

Similar Publications

Background: Sporadic aortic aneurysm and dissection (AAD) is a critical condition characterised by the progressive loss of vascular smooth muscle cells (VSMCs) and the breakdown of the extracellular matrix. However, the molecular mechanisms responsible for the phenotypic switch and loss of VSMCs in AAD are not fully understood.

Methods And Results: In this study, we employed a discovery-driven, unbiased approach.

View Article and Find Full Text PDF

Vascular stabilization is a mechanosensitive process, in part driven by blood flow. Here, we demonstrate the involvement of the mechanosensitive ion channel, Piezo1, in promoting arterial accumulation of vascular smooth muscle cells (vSMCs) during zebrafish development. Using a series of small molecule antagonists or agonists to temporally regulate Piezo1 activity, we identified a role for the Piezo1 channel in regulating klf2a, a blood flow responsive transcription factor, expression levels and altered targeting of vSMCs between arteries and veins.

View Article and Find Full Text PDF

The need for a permanent pacemaker (PPM) implantation after surgical aortic valve implantation (SAVR) is a recognized postoperative complication, with potentially long-term reduced survival. From 1987 to 2017, 2500 consecutive patients underwent SAVR with a biological valve with or without concomitant procedures such as CABG or mitral valve repair. Mechanical valves or valves in another position were excluded.

View Article and Find Full Text PDF

Bioprosthetic aortic valve degeneration (BAVD) is a significant clinical concern following both transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR). The increasing use of bioprosthetic valves in aortic valve replacement in younger patients and the subsequent rise in cases of BAVD are acknowledged in this review which aims to provide a comprehensive overview of the incidence, diagnosis, predictors, and management of BAVD. Based on a thorough review of the existing literature, this article provides an updated overview of the biological mechanisms underlying valve degeneration, including calcification, structural deterioration, and inflammatory processes and addresses the various risk factors contributing to BAVD, such as patient demographics, comorbidities, and procedural variables.

View Article and Find Full Text PDF

Venous Endothelial Cell Transcriptomic Profiling Implicates METAP1 in Preeclampsia.

Circ Res

December 2024

Cardiovascular Research Center, Massachusetts General Hospital, Boston. (C.C., P.X., Z.Y., Y.S., E.S.L., J.D.R., M.C.H.).

Background: Preeclampsia is a hypertensive disorder of pregnancy characterized by systemic endothelial dysfunction. The pathophysiology of preeclampsia remains incompletely understood. This study used human venous endothelial cell (EC) transcriptional profiling to investigate potential novel mechanisms underlying EC dysfunction in preeclampsia.

View Article and Find Full Text PDF