This study investigates the effect of varying test conditions including ambient temperature (19, 22, and 25 °C), mass charges of R600a refrigerant (40, 50, 60, and 70 g), and concentrations of TiO nanolubricant (0, 0.2 and 0.4 g/L) on the performance of a slightly modified 100g R134a domestic refrigeration system. The investigated parameters include evaporator air temperature, energy consumption, coefficient of performance, and second law efficiency of the system. The results showed that the performance of the refrigeration system at 0.2 and 0.4 g/L concentrations of TiO nanolubricant, improved at optimum ambient temperature and R600a mass charge conditions. At optimum conditions, the evaporator air temperature and energy consumption reduced within the range 5.26 to 26.32 %, and 0.13 to 14.09 % respectively, while the coefficient of performance and second law efficiency increased within the range 0.05 to 16.32 %, and 2.8 to 16 %, respectively. However, at other conditions (non-optimum), the energy consumption and evaporator air temperature were higher and within the range 0.28 to 8.26 %, and 5 to 40 % respectively, while the coefficient of performance and second law efficiency reduced within the range 2.99 to 10.94 %, and 0.55 to 13.43 % respectively. In conclusion, we observed variations in the performance of the refrigerator with varying test conditions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7892924PMC
http://dx.doi.org/10.1016/j.heliyon.2021.e06156DOI Listing

Publication Analysis

Top Keywords

concentrations tio
12
evaporator air
12
air temperature
12
energy consumption
12
coefficient performance
12
performance second
12
second law
12
law efficiency
12
refrigerator varying
8
r600a refrigerant
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!