Purpose The purpose of this study is to examine five-year outcomes of trabeculectomy and compare the stand-alone procedure when combined with phacoemulsification. Patients and methods This study included 123 eyes of 109 patients, with 79 patients in the trabeculectomy group and 44 patients in the phacotrabeculectomy group. Non-randomized comparative cohort study with data collected retrospectively from an existing database compiled by a single surgeon operating in Sydney, Australia from 2007 to 2019. The primary outcome measure was intraocular pressure. Secondary outcome measures were a number of glaucoma medications, treatment success rates, best-corrected visual acuity, bleb morphology, post-operative complications, and re-operation rate. Results The mean intraocular pressure was 10.6 ± 2.7 mm Hg in the trabeculectomy group (pre-operative mean intraocular pressure of 28.0 ± 9.8) and 12.0 ± 3.0 mm Hg in the phacotrabeculectomy group (pre-operative mean intraocular pressure of 23.4 ± 7.9) after five years (P = 0.052). The number of glaucoma medications required was 0.3 ± 0.7 in the trabeculectomy group (pre-operative mean of 3.7 ± 1.1) and 1.3 ± 1.2 in the phacotrabeculectomy group (pre-operative mean of 3.1 ± 1.0, P < 0.001). Conclusions Intraocular pressure reduction post-operatively over five years was similar between trabeculectomy and phacotrabeculectomy as determined by mean intraocular pressure, and intraocular pressure reduction from baseline. However, fewer supplemental glaucoma medications were required following trabeculectomy as compared to the combined procedure.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7920213PMC
http://dx.doi.org/10.7759/cureus.12950DOI Listing

Publication Analysis

Top Keywords

intraocular pressure
28
group pre-operative
16
trabeculectomy group
12
phacotrabeculectomy group
12
glaucoma medications
12
five-year outcomes
8
outcomes trabeculectomy
8
trabeculectomy phacotrabeculectomy
8
number glaucoma
8
pre-operative intraocular
8

Similar Publications

Purpose: This study evaluates the effect of 6° horizontal gaze tolerance on visual field mean sensitivity (MS) in patients with glaucoma using a binocular head-mounted automated perimeter, following findings of structural changes in the posterior globe from magnetic resonance imaging and optical coherence tomography.

Methods: In this cross-sectional study, a total of 161 eyes (85 primary open-angle glaucoma [POAG] and 76 healthy) from 117 participants were included. Logistic regression and 1:1 matched analysis assessed the propensity score for glaucoma and healthy eyes, considering age, sex, and axial length as confounders.

View Article and Find Full Text PDF

Purpose: Descemet membrane endothelial keratoplasty (DMEK) has emerged as a novel approach in corneal transplantation over the past two decades. This study aims to identify predisposing risk factors for post-DMEK ocular hypertension (OHT) and develop a preoperative predictive model for post-DMEK OHT.

Methods: Patients who underwent DMEK at Gangnam Severance Hospital between 2017 and 2024 were included in the study.

View Article and Find Full Text PDF

Biomimetic Air-Lifted Organ Culture System with a Protective Coverage Membrane for Full-Thickness Corneal Preservation.

ACS Biomater Sci Eng

January 2025

Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, Guangdong 518055, China.

Effective storage and utilization of limited donor corneal resources are in high demand to alleviate the shortage of donor corneal tissue. Here, we designed a static air-lifted organ culture system equipped with a protective coverage membrane, namely, an air-lifted OC-P system, to provide a biomimetic physiological environment for full-thickness corneal preservation. The air-lifted OC-P system features a unique collagen-based protective coverage membrane that can offer a moist, oxygen-rich environment for corneal epithelium, produce an appropriate intraocular pressure onto the cornea by gravity, and facilitate the maintenance of the organ culture medium level for nutrient supply during corneal preservation.

View Article and Find Full Text PDF

Patient Perspectives on Home Tonometer Usage for Glaucoma.

Clin Ophthalmol

January 2025

Department of Ophthalmology and Visual Sciences, W. K. Kellogg Eye Center, University of Michigan Medical School, Ann Arbor, MI, USA.

Purpose: To understand patient experiences using the iCare HOME tonometer through assessing ease of use, device usage patterns, proficiency, and patient comments.

Methods: We conducted a prospective survey-based cohort study of 19 patients (35 eyes) with glaucoma or glaucoma suspect diagnoses. Patients received training on home tonometer usage and were loaned the device for one week to measure intraocular pressure at home multiple times daily.

View Article and Find Full Text PDF

Purpose: To determine the effect on intraocular pressure (IOP) of switching to a once-daily netarsudil/latanoprost fixed dose combination (FDC) from various topical treatment regimens including latanoprost monotherapy or latanoprost combined with other IOP-lowering agents for the treatment of open-angle glaucoma or ocular hypertension.

Methods: A total of 136 participants enrolled. Eligible participants were aged ≥18 years and had a current diagnosis of open-angle glaucoma or ocular hypertension.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!