To obtain high performance (matching, mechanical properties, and biocompatibility) of personalized biomechanical fixation-type tibial implants, three-dimensional reconstruction was performed using a combination of reverse and positive methods. The implant design was optimized using a topological optimization method, the shape-optimized B-unit structure was filled, and the performance was evaluated for implants prepared by direct forming technology of Selective Laser Melting (3D Printing). The results show obviously reduced weight of the tibial implant, increased stress and displacement, yet with a more uniform distribution. The mechanical properties of the tibial implant were lower than those of the B-units, the weight was lighter, and the stress distribution was more uniform. The surface of the tibial implants prepared by SLM appeared clean and bright, the metal texture was good, the structure between the porous struts was clear, the surface had low powder adhesion, the lap joint was good, and no obvious warping deformation or forming defects were observed. The results of this study provide a foundation for the direct application of high performance personalized biofixation implants.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jmbbm.2021.104415 | DOI Listing |
J Arthroplasty
January 2025
Georgetown University School of Medicine, MedStar Georgetown University Hospital, Washington, D.C, USA. Electronic address:
Introduction: As the number of revision total knee arthroplasties (rTKA) continues to rise, there is increasing interest in the use of contemporary rotating hinge prostheses. These devices often incorporate porous cones to fill bone defects and enhance long-term fixation. This study evaluated the clinical and functional outcomes and survivorship in rTKA patients utilizing a rotating hinge prosthesis with flexible titanium (FT) cones, porous tantalum (PT) cones, or no cones.
View Article and Find Full Text PDFJ Clin Med
January 2025
Servicio de Cirugía Ortopédica y Traumatología, Hospital La Paz-IdiPaz, 28046 Madrid, Spain.
: Surgical accuracy in total knee replacement (TKR) may vary with the surgeon, the patient preoperative deformity, and the guiding system to perform the procedure. Navigation systems attempt to increase the intraoperative information the surgeon requires to make the appropriate decisions, sometimes associating cumbersome procedures and unclear effectiveness to place the implant more precisely than conventional instruments. : We conducted a retrospective case-control study with prospective data collection of radiographic measurements (alignment, joint line and patellar height) in a sample of 100 consecutive patients receiving TKR Optetrak Logic PS, either with standard surgical technique with Trulion Instrumentation ( = 59) or with the Guided Personalized Surgery (GPS) system ( = 41).
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Orthopedic Surgery, Anam Hospital, Korea University College of Medicine, 73 Goryeodae-ro Seongbuk-gu, Seoul 02841, Republic of Korea.
Distal tibia fractures are high-energy injuries characterized by a mismatch between standard plate designs and the patient's specific anatomical bone structure, which can lead to severe soft tissue damage. Recent advancements have focused on the development of customized metal plates using three-dimensional (3D) printing technology. However, 3D-printed metal plates using titanium alloys have not incorporated a locking system due to the brittleness of these alloys.
View Article and Find Full Text PDFEur J Trauma Emerg Surg
January 2025
Bowen University Teaching Hospital, P. O. Box 15, Ogbomoso, Oyo State, Nigeria.
Purpose: To investigate the factors that prolonged the operative duration (OD) in patients who underwent single-stage locked intramedullary nailing of their multiple concurrent long-bone fractures (LBFs) using Surgical Implant Generation Network (SIGN) nails.
Methods: Forty-nine patients who fulfilled the inclusion criteria were enrolled prospectively over 8½ years. Data collected included age, sex, injury mechanism and severity, fracture characteristics, nail types and diameter, OD, fracture-to-fixation time, length of hospital stay (LOS), functional outcomes and complications.
Eur J Trauma Emerg Surg
January 2025
Department of Trauma Surgery, University Medical Centre Groningen, University of Groningen, Groningen, The Netherlands.
Purpose: The aim of this study was to evaluate the feasibility of using patient-specific implants (PSI) for complex shaft corrective osteotomies in multiplanar deformities of long bones in the lower extremities. Additionally, it aimed to investigate the added value of these implants by quantifying surgical accuracy on postoperative CT, comparing their outcomes to two commonly used techniques: 3D virtual visualizations and 3D-printed surgical guides.
Methods: Six tibial and femoral shaft corrective osteotomies were planned and performed on three Thiel embalmed human specimen.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!