In lithography, misalignment measurement with a large range and high precision in two dimensions for the overlay is a fundamental but challenging problem. For moiré-based misalignment measurement schemes, one potential solution is considered to be the use of circular gratings, whose formed moiré fringes are symmetric, isotropic, and aperiodic. However, due to the absence of proper analytical arithmetic, the measurement accuracy of such schemes is in the tens of nanometers, resulting in their application being limited to only coarse alignments. To cope with this problem, we propose a novel deep learning-based misalignment measurement strategy inspired by deep convolutional neural networks. The experimental results show that the proposed scheme can achieve nanoscale accuracy with micron-scale circular alignment marks. Relative to the existing strategies, this strategy has much higher precision in misalignment measurement and much better robustness to fabrication defects and random noise. This enables a one-step two-dimensional nanoscale alignment scheme for proximity, x-ray, extreme ultraviolet, projective, and nanoimprint lithographies.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.414617DOI Listing

Publication Analysis

Top Keywords

misalignment measurement
16
deep learning-based
8
circular gratings
8
measurement
5
learning-based moiré-fringe
4
moiré-fringe alignment
4
alignment circular
4
gratings lithography
4
lithography lithography
4
misalignment
4

Similar Publications

Circadian Misalignment Impacts Cardiac Autonomic Modulation in Adolescence.

Sleep

January 2025

Sleep Research & Treatment Center, Department of Psychiatry & Behavioral Health, Penn State University, College of Medicine, Hershey PA, USA.

Study Objectives: Although heart rate variability (HRV), a marker of cardiac autonomic modulation (CAM), is known to predict cardiovascular morbidity, the circadian timing of sleep (CTS) is also involved in autonomic modulation. We examined whether circadian misalignment is associated with blunted HRV in adolescents as a function of entrainment to school or on-breaks.

Methods: We evaluated 360 subjects from the Penn State Child Cohort (median 16y) who had at least 3-night at-home actigraphy (ACT), in-lab 9-h polysomnography (PSG) and 24-h Holter-monitoring heart rate variability (HRV) data.

View Article and Find Full Text PDF

Quantifying tear exchange during rigid contact lens wear using corneoscleral profilometry: A proof of concept study.

Ophthalmic Physiol Opt

January 2025

Contact Lens and Visual Optics Laboratory, Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia.

Introduction: Tear exchange during contact lens wear is essential for ocular surface integrity, facilitating debris removal, and maintaining corneal metabolism. Fluorophotometry and fluorogram methods are typically used to measure tear exchange, which require hardware modifications to a slit lamp biomicroscope. This manuscript introduces an alternative method using a corneoscleral profilometer, the Eye Surface Profiler (ESP), to quantify tear exchange during corneal and scleral rigid lens wear by assessing fluorescence intensity changes over time.

View Article and Find Full Text PDF

Introduction: Body composition is studied in athletes as a means of measuring physical fitness and progression of training. Athletes can utilize body composition in multiple ways to guide training toward athlete specific goals. Several different methods exist with varying levels of cost, invasiveness, reading complexity, and availability.

View Article and Find Full Text PDF

This article provides a guide for rigorous, theory-driven measurement approaches, proposing best practices for the scientific study of systemic racism in health research. We argue that the analytical crux of measuring systemic racism-a complex, interconnected, and dynamic system-lies in operationalizing the collective logics, properties, and mechanisms that undergird racial inequities. Misalignment between measurement tools and these foundational features undermines research validity, as incongruent measures distort findings and obscure systemic racism's true impacts.

View Article and Find Full Text PDF

Objectives: The aim is to assess the feasibility and accuracy of a novel quantitative ultrasound (US) method based on global speed-of-sound (g-SoS) measurement using conventional US machines, for breast density assessment in comparison to mammographic ACR (m-ACR) categories.

Materials And Methods: In a prospective study, g-SoS was assessed in the upper-outer breast quadrant of 100 women, with 92 of them also having m-ACR assessed by two radiologists across the entire breast. For g-SoS, ultrasonic waves were transmitted from varying transducer locations and the image misalignments between these were then related analytically to breast SoS.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!