The microscopic visualization of large-scale three-dimensional (3D) samples by optical microscopy requires overcoming challenges in imaging quality and speed and in big data acquisition and management. We report a line-illumination modulation (LiMo) technique for imaging thick tissues with high throughput and low background. Combining LiMo with thin tissue sectioning, we further develop a high-definition fluorescent micro-optical sectioning tomography (HD-fMOST) method that features an average signal-to-noise ratio of 110, leading to substantial improvement in neuronal morphology reconstruction. We achieve a >30-fold lossless data compression at a voxel resolution of 0.32 × 0.32 × 1.00 μm, enabling online data storage to a USB drive or in the cloud, and high-precision (95% accuracy) brain-wide 3D cell counting in real time. These results highlight the potential of HD-fMOST to facilitate large-scale acquisition and analysis of whole-brain high-resolution datasets.

Download full-text PDF

Source
http://dx.doi.org/10.1038/s41592-021-01074-xDOI Listing

Publication Analysis

Top Keywords

line-illumination modulation
8
high-definition imaging
4
imaging line-illumination
4
modulation microscopy
4
microscopy microscopic
4
microscopic visualization
4
visualization large-scale
4
large-scale three-dimensional
4
three-dimensional samples
4
samples optical
4

Similar Publications

Traditional line-scan Raman imaging features a rapid imaging speed while preserving complete spectral information, yet has diffraction-limited resolution. Sinusoidally structured line excitation can yield an improvement in the lateral resolution of the Raman image along the line's direction. However, given the need for the line and spectrometer slit to be aligned, the resolution in the perpendicular direction remains diffraction limited.

View Article and Find Full Text PDF

Single-scan HiLo with line-illumination strategy for optical section imaging of thick tissues.

Biomed Opt Express

April 2021

Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China.

Optical sectioning has been widely employed for inhibiting out-of-focus backgrounds in three-dimensional (3D) imaging of biological samples. However, point scanning imaging or multiple acquisitions for wide-field optical sectioning in epi-illumination microscopy remains time-consuming for large-scale imaging. In this paper, we propose a single-scan optical sectioning method based on the hybrid illumination (HiLo) algorithm with a line-illumination strategy.

View Article and Find Full Text PDF

Background: High resolution imaging is desirable for advanced study and clinical management of retinal diseases. However, spatial resolution of retinal imaging has been limited due to available numerical aperture and optical aberration of the ocular optics. This study is to develop and validate virtually structured detection (VSD) to surpass diffraction limit for resolution improvement in retinal imaging of awake human.

View Article and Find Full Text PDF

High-definition imaging using line-illumination modulation microscopy.

Nat Methods

March 2021

Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, China.

The microscopic visualization of large-scale three-dimensional (3D) samples by optical microscopy requires overcoming challenges in imaging quality and speed and in big data acquisition and management. We report a line-illumination modulation (LiMo) technique for imaging thick tissues with high throughput and low background. Combining LiMo with thin tissue sectioning, we further develop a high-definition fluorescent micro-optical sectioning tomography (HD-fMOST) method that features an average signal-to-noise ratio of 110, leading to substantial improvement in neuronal morphology reconstruction.

View Article and Find Full Text PDF

Confocal scanning microscopy is the standard modality for fluorescence imaging. Point scanning, however, leads to a limited throughput and makes the technique unsuitable for fast multi-focal scanning over large areas. We propose an architecture for multi-focal fluorescence imaging that is scalable to large area imaging.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!