Imaging atomically resolved surfaces and performing spectroscopy of exotic surfaces at cryogenic temperature in the presence of the magnetic field is an engineering challenge. Additionally, performing these measurements in an all-cryogen-free environment compounds the above complexity due to the associated vibration and acoustic noise generated by the running of cryogenic cold heads. We here report successful integration of a cryogen-free scanning tunneling microscope (STM) with a cryogen-free superconducting vector-magnet, connected to an ultra-high vacuum cluster assembly for in situ sample transfer. We present details of the integration involving vibration and electrical noise isolation procedures allowing for operation of the STM at extremely low noise levels below 30 fA/Hz during normal operations of the complete vacuum-line assembly with multiple turbomolecular pumps. We demonstrate the above STM capability at cryogenic temperature and in the presence of the magnetic field through atomic resolution imaging of graphite and thin films of gold on the mica substrate transferred in situ to the STM chamber. We also demonstrate spectroscopy signatures of the superconducting gap in MgB thin films. The design of our in-house customized cluster-vacuum-line assembly provides unsought opportunities in continuous uninterrupted imaging of ultra-clean in-vacuum grown surfaces without the need for cryogenic refills in either the STM or the magnet.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0041037DOI Listing

Publication Analysis

Top Keywords

low noise
8
cryogen-free scanning
8
scanning tunneling
8
sample transfer
8
surfaces cryogenic
8
cryogenic temperature
8
temperature presence
8
presence magnetic
8
magnetic field
8
thin films
8

Similar Publications

Rising computed tomography (CT) workloads require more efficient image interpretation methods. Digitally reconstructed radiographs (DRRs), generated from CT data, may enhance workflow efficiency by enabling faster radiological assessments. Various techniques exist for generating DRRs.

View Article and Find Full Text PDF

Lightweight Retinal Layer Segmentation With Global Reasoning.

IEEE Trans Instrum Meas

May 2024

School of Mechanical Engineering, Shandong University, Jinan 250061, Shandong, China.

Automatic retinal layer segmentation with medical images, such as optical coherence tomography (OCT) images, serves as an important tool for diagnosing ophthalmic diseases. However, it is challenging to achieve accurate segmentation due to low contrast and blood flow noises presented in the images. In addition, the algorithm should be light-weight to be deployed for practical clinical applications.

View Article and Find Full Text PDF

With the rapid development of tourism, the concentration of visitor flows poses significant challenges for public safety management, especially in low-light and highly occluded environments, where existing pedestrian detection technologies often struggle to achieve satisfactory accuracy. Although infrared images perform well under low-light conditions, they lack color and detail, making them susceptible to background noise interference, particularly in complex outdoor environments where the similarity between heat sources and pedestrian features further reduces detection accuracy. To address these issues, this paper proposes the FusionU10 model, which combines information from both infrared and visible light images.

View Article and Find Full Text PDF

Evaluation of charge summing correction in CdTe-based photon-counting detectors for breast CT: performance metrics and image quality.

J Med Imaging (Bellingham)

January 2025

U.S. Food and Drug Administration, Office of Science and Engineering Labs, Division of Imaging, Diagnostics, and Software Reliability, Silver Spring, Maryland, United States.

Purpose: We evaluate the impact of charge summing correction on a cadmium telluride (CdTe)-based photon-counting detector in breast computed tomography (CT).

Approach: We employ a custom-built laboratory benchtop system using the X-THOR FX30 0.75-mm CdTe detector (Varex Imaging, Salt Lake City, Utah, United States) with a pixel pitch of 0.

View Article and Find Full Text PDF

Wide dynamic range compression (WDRC) and noise reduction both play important roles in hearing aids. WDRC provides level-dependent amplification so that the level of sound produced by the hearing aid falls between the hearing threshold and the highest comfortable level of the listener, while noise reduction reduces ambient noise with the goal of improving intelligibility and listening comfort and reducing effort. In most current hearing aids, noise reduction and WDRC are implemented sequentially, but this may lead to distortion of the amplitude modulation patterns of both the speech and the noise.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!