A field programmable gate array based high speed real-time weak periodic signal detection technique.

Rev Sci Instrum

State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei 230026, China.

Published: February 2021

The detection of a high repetition rate weak signal is studied in this paper. Owing to the characteristics of the signal of interest, both high speed analog-to-digital converter (ADC) and low computational complexity data processing techniques are required for high speed real-time weak signal detection. In this paper, a novel field programmable gate array (FPGA) based high speed real-time periodic weak signal detection technique is presented. Cascaded comparators outside the FPGA and cascaded flip flops in the FPGA are used to implement a one-bit ADC, which performs quantization first followed by sampling. Based on this novel design, a time-interleaved structure with several sub-channels is further proposed to significantly improve the sampling rate of the one-bit ADC, which does not require calibration for offset, gain, and sample-time mismatches between sub-channels. Each sub-channel has a long-time coherent integration structure to coherently integrate the sampled one-bit data. A full layer clearance mechanism that only operates on specific bits of the integrated sums is proposed to overcome the influence of a noise baseline drift on the weak signal detection. Compared with the traditional adaptive threshold, this mechanism has a significantly lower computational complexity. A prototype with three sub-channels performing 1.5 Gs/s sampling is implemented to verify the proposed technique. The results obtained confirm its high sampling rate and noise baseline drift tolerance in weak signal detection.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0037067DOI Listing

Publication Analysis

Top Keywords

signal detection
20
weak signal
20
high speed
16
speed real-time
12
field programmable
8
programmable gate
8
gate array
8
based high
8
real-time weak
8
detection technique
8

Similar Publications

Molecularly imprinted hydrogels embedded with two-dimensional photonic crystals for the detection of dexamethasone/betamethasone sodium phosphate.

Mikrochim Acta

January 2025

Key Laboratory of New Energy & New Functional Materials, Shaanxi Key Laboratory of Chemical Reaction Engineering, College of Chemistry and Chemical Engineering, School of Medicine, Yan'an University, Yan'an, Shaanxi, 716000, People's Republic of China.

Dexamethasone sodium phosphate (DSP) and betamethasone sodium phosphate (BSP) imprinted hydrogels embedded with two-dimensional photonic crystals (2DPC) were developed as hormones-sensitive photonic hydrogel sensors with highly sensitive, selective, anti-interference and reproducible recognition capability. The DSP/BSP molecularly imprinted photonic hydrogels (denoted as DSP-MIPH and BSP-MIPH) can specifically recognize DSP/BSP by rebinding the DSP/BET molecules to nanocavities in the hydrogel network. This recognition is enabled by the similar shape, size, and binding sites of the nanocavities to the target molecules.

View Article and Find Full Text PDF

Nicotinamide adenine dinucleotide is a crucial coenzyme in cellular metabolism and is implicated in various diseases. This work introduces an electrochemical bioanalytical method utilizing solution-phase formate dehydrogenase (CbFDH) for detecting its oxidized form (NAD) in human blood plasma samples. The detection mechanism involves the catalytic conversion of NAD to NADH, facilitated by CbFDH in the presence of formate.

View Article and Find Full Text PDF

Nanomaterials and clinical SERS technology: broad applications in disease diagnosis.

J Mater Chem B

January 2025

Ningbo Key Laboratory of Biomedical Imaging Probe Materials and Technology, Laboratory of Advanced Theranostic Materials and Technology, Chinese Academy of Sciences (CAS) Key Laboratory of Magnetic Materials and Devices, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201, China.

The critical need for rapid cancer diagnosis and related illnesses is growing alongside the current healthcare challenges, unfavorable prognosis, and constraints in diagnostic timing. As a result, emphasis on surface-enhanced Raman spectroscopy (SERS) diagnostic methods, including both label-free and labelled approaches, holds significant promise in fields such as analytical chemistry, biomedical science, and physics, due to the user-friendly nature of SERS. Over time, the SERS detection sensitivity and specificity with nanostructured materials for SERS applications (NMs-SERS) in different media have been remarkable.

View Article and Find Full Text PDF

Characterization of Optokinetic Nystagmus in Healthy Participants With a Novel Oculography Device.

Otolaryngol Head Neck Surg

January 2025

Department of Otolaryngology-Head and Neck Surgery, Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts, USA.

Objective: To develop a proof-of-concept smart-phone-based eye-tracking algorithm to assess non-pathologic optokinetic (OKN) nystagmus in healthy participants. Current videonystagmography (VNG) is typically restricted to in-office use, and advances in portable vestibular diagnostics would yield immense public health benefits.

Study Design: Prospective cohort study.

View Article and Find Full Text PDF

This study presents an innovative glucose detection platform, featuring a highly sensitive, non-enzymatic glucose sensor. The sensor integrates nickel nanowires and a graphene thin film deposited on the gate region of an extended-gate electric double-layer field-effect transistor (EGEDL-FET). This unique combination of materials and device structure enables superior glucose sensing performance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!