Material extrusion (ME) desktop 3D printing is known to strongly emit nanoparticles (NP), and the need for risk management has been recognized widely. Four different engineering control measures were studied in real-life office conditions by means of online NP measurements and indoor aerosol modeling. The studied engineering control measures were general ventilation, local exhaust ventilation (LEV), retrofitted enclosure, and retrofitted enclosure with LEV. Efficiency between different control measures was compared based on particle number and surface area (SA) concentrations from which SA concentration was found to be more reliable. The study found out that for regular or long-time use of ME desktop 3D printers, the general ventilation is not sufficient control measure for NP emissions. Also, the LEV with canopy hood attached above the 3D printer did not control the emission remarkably and successful position of the hood in relation to the nozzle was found challenging. Retrofitted enclosure attached to the LEV reduced the NP emissions 96% based on SA concentration. Retrofitted enclosure is nearly as efficient as enclosure attached to the LEV (reduction of 89% based on SA concentration) but may be considered more practical solution than enclosure with LEV.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/ina.12791 | DOI Listing |
Sci Total Environ
May 2023
Institut de Ciència i Tecnologia Ambientals ICTA-UAB MdM Unit (CEX2019-0940-M), Universitat Autònoma de Barcelona (UAB), Bellaterra, Spain; Department of Chemical, Biological and Environmental Engineering, Universitat Autònoma de Barcelona (UAB), Bellaterra, Spain. Electronic address:
Urban green installations are extensively promoted to increase sustainable and accessible food production and simultaneously improve the environmental performance and liveability of city buildings. In addition to the multiple benefits of plant retrofitting, these installations may lead to a consistent increase in biogenic volatile organic compounds (BVOCs) in the urban environment, especially indoors. Accordingly, health concerns could limit the implementation of building-integrated agriculture.
View Article and Find Full Text PDFIndoor Air
July 2021
Finnish Institute of Occupational Health, Helsinki, Finland.
Material extrusion (ME) desktop 3D printing is known to strongly emit nanoparticles (NP), and the need for risk management has been recognized widely. Four different engineering control measures were studied in real-life office conditions by means of online NP measurements and indoor aerosol modeling. The studied engineering control measures were general ventilation, local exhaust ventilation (LEV), retrofitted enclosure, and retrofitted enclosure with LEV.
View Article and Find Full Text PDFJ Agromedicine
October 2019
Occupational Medicine Division and Centre for Environmental and Occupational Health Research, School of Public Health and Family Medicine, Faculty of Health Sciences, University of Cape Town, Cape Town, South Africa.
Occupational hazards exist in the processing of seafood both in land-based facilities as well as on board vessels. Recent findings on occupational injury and respiratory health risks among seafood processing workers were presented and discussed at the IFISH5 conference. Particular emphasis was put on the challenges that im/migrant workers encounter, the greater risks onboard factory vessels, especially where processing machinery are retrofitted to older vessels not primarily designed for this purpose, and the difficulties in assessing and preventing bioaerosol exposures and associated respiratory health risks despite recent advances in characterising agents responsible for allergic and non-allergic reactions.
View Article and Find Full Text PDFProc SPIE Int Soc Opt Eng
February 2016
Chemical and Biomolecular Engineering, University of South Alabama, AL 36688.
Colorectal cancer is the United States 3rd leading cancer in death rates. The current screening for colorectal cancer is an endoscopic procedure using white light endoscopy (WLE). There are multiple new methods testing to replace WLE, for example narrow band imaging and autofluorescence imaging.
View Article and Find Full Text PDFTechnol Cancer Res Treat
February 2016
Department of Radiation Medicine, Loma Linda University Medical Center, Loma Linda, CA, USA
Purpose: To evaluate the scattered and secondary radiation fields present in and around a passive proton treatment nozzle. In addition, based on these initial tests and system reliability analysis, to develop, install, and evaluate a radiation shielding structure to protect sensitive electronics against single-event effects (SEE) and improve system reliability.
Methods And Materials: Landauer Luxel+ dosimeters were used to evaluate the radiation field around one of the gantry-mounted passive proton delivery nozzles at Loma Linda University Medical Center's James M Slater, MD Proton Treatment and Research Center.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!