Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The aim of the present study was to determine the parameters characterising the blood flow velocity in the fetal heart and aorta in goats by Doppler ultrasonography. Twenty-four Bulgarian White milk goats, aged 4-6 years, weighing 45-51 kg were used in the study. Doppler ultrasound measurements of the blood flow velocity in fetal heart were done at the end of first, second and third trimesters of pregnancy, and in the fetal aorta - at the end of the second and third trimesters of pregnancy. Ultrasound investigations were carried out by transabdominal approach with linear and convex transducers, with frequency 8.0 MHz. Blood flow parameters that included maximum and minimum systolic velocity, end-diastolic velocity, pulsatility index, resistance index and systolic/diastolic ratio were measured by spectral Doppler ultrasonography. The results showed that the highest maximum systolic velocity in the fetal heart was observed at the end of the first pregnancy trimester. Statistically significantly (p < 0.05) lower values of this parameter were registered in the second and third pregnancy trimesters. A similar tendency was observed for minimum systolic velocity, end-diastolic velocity and systolic/diastolic ratio. The pulsatility index and resistance index had similar values for the three studied periods. Examination of the fetal aorta showed statistically significant differences (p < 0.05) of minimum systolic velocity, end-diastolic velocity, pulsatility and resistance index in the third, compared with the second trimester of pregnancy. The analysis of the results suggested that Doppler ultrasonography can be used to monitor fetal blood flow changes during the various stages of pregnancy.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8294397 | PMC |
http://dx.doi.org/10.1002/vms3.463 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!