AI Article Synopsis

  • Developed a high-efficiency microfluidic chip that isolates exosomes from human plasma using nanoporous membrane and agarose gel electrophoresis.
  • Characterized extracted exosomes using techniques like transmission electron microscopy and Western blotting, comparing isolation efficiency between the microfluidic method and ultracentrifugation.
  • The microfluidic chip demonstrated 3.80 times higher yield than ultracentrifugation for small plasma volumes, indicating its potential in speeding up exosomal analysis and cancer research.

Article Abstract

We developed a high-efficiency microfluidic chip for extracting exosomes from human plasma. We collected peripheral blood from normal human, designed and fabricated a microfluidic chip based on nanoporous membrane and agarose gel electrophoresis to isolate exosomes. The extracted exosomes were characterized by transmission electron microscopy, nanosight and Western blotting, the morphology, concentration and particle size of exosomes were identified and analyzed. Meanwhile, we used ultracentrifugation and microfluidic chip to isolate exosomes separately. The particle size and concentration of the exosomes extracted by two methods were compared and analyzed, and their respective extraction efficiency was discussed. Finally, the expression level of miRNA-21 in exosomes was analyzed by RT-PCR. The microfluidic chip isolated (in 1 hour) high-purity exosomes with size ranging from 30-200 nm directly from human plasma, allowing downstream exosomal miRNA analysis. By comparing with ultracentrifugation, the isolation yield of microfluidic chip was 3.80 times higher than ultracentrifugation when the volume of plasma sample less than 100 μL. The optimized parameters for exosome isolation by gel electrophoresis microfluidic chip were: voltage: 100 V; concentration of agarose gel: 1.0%; flow rate of injection pump: 0.1 mL/h. The gel electrophoresis microfluidic chips could rapidly and efficiently isolate the exosomes, showing great potential in the research of exosomes and cancer biomarkers.

Download full-text PDF

Source
http://dx.doi.org/10.13345/j.cjb.200376DOI Listing

Publication Analysis

Top Keywords

microfluidic chip
28
gel electrophoresis
16
electrophoresis microfluidic
12
isolate exosomes
12
exosomes
10
microfluidic
8
human plasma
8
agarose gel
8
exosomes extracted
8
particle size
8

Similar Publications

Manufacturing of Liposomes Using a Stainless-Steel Microfluidic Device: An Investigation into Design of Experiments.

Langmuir

January 2025

Department of Polymer and Materials Chemistry, Faculty of Chemistry & Petroleum Sciences, Shahid Beheshti University, P.O. Box 1983969411 Tehran, Iran.

Liposomes are highly beneficial nanocarrier systems due to their biocompatibility, low toxicity, and exceptional inclusiveness, which lead to improved drug bioavailability. For biological applications, accurate control over these nanoparticles' mean size and size distribution is essential. Micromixers facilitate the continuous production of liposomes, enhancing the precision of size regulation and reproducibility.

View Article and Find Full Text PDF

Advancing diagnostics and disease modeling: current concepts in biofabrication of soft microfluidic systems.

In Vitro Model

June 2024

3B's Research Group, European Institute of Excellence in Tissue Engineering and Regenerative Medicine Headquarters, Parque de Ciência e Tecnologia, I3Bs - Research Institute on Biomaterials, Biodegradable and Biomimetics - University of Minho, Zona Industrial da Gandra - Avepark, Barco, Guimaraes, 4805-017 Portugal.

Soft microfluidic systems play a pivotal role in personalized medicine, particularly in in vitro diagnostics tools and disease modeling. These systems offer unprecedented precision and versatility, enabling the creation of intricate three-dimensional (3D) tissue models that can closely emulate both physiological and pathophysiological conditions. By leveraging innovative biomaterials and bioinks, soft microfluidic systems can circumvent the current limitations involving the use of polydimethylsiloxane (PDMS), thus facilitating the development of customizable systems capable of sustaining the functions of encapsulated cells and mimicking complex biological microenvironments.

View Article and Find Full Text PDF

Cardiac organ chip: advances in construction and application.

Biomater Transl

November 2024

Guangdong Provincial Key Laboratory of Construction and Detection in Tissue Engineering, School of Basic Medical Science, Southern Medical University, Guangzhou, Guangdong Province, China.

Cardiovascular diseases are a leading cause of death worldwide, and effective treatment for cardiac disease has been a research focal point. Although the development of new drugs and strategies has never ceased, the existing drug development process relies primarily on rodent models such as mice, which have significant shortcomings in predicting human responses. Therefore, human-based in vitro cardiac tissue models are considered to simulate physiological and functional characteristics more effectively, advancing disease treatment and drug development.

View Article and Find Full Text PDF

Unlabelled: Neuroblastoma (NB) is a highly vascularized pediatric tumor arising from undifferentiated neural crest cells early in life, exhibiting both traditional endothelial-cell-driven vasculature and an intriguing alternative vasculature. The alternative vasculature can arise from cancer cells undergoing transdifferentiation into tumor-derived endothelial cells (TEC), a trait associated with drug resistance and tumor relapse. The lack of effective treatments targeting NB vasculature primarily arises from the challenge of establishing predictive in vitro models that faithfully replicate the alternative vasculature phenomenon.

View Article and Find Full Text PDF

Centrifugation is crucial for size and density-based sample separation, but low-volume or delicate samples suffer from loss and impurity issues during repeated spins. We introduce the "Spinochip", a novel microfluidic system utilizing centrifugal forces for efficient filling of dead-end microfluidic channels. The Spinochip enables versatile fluid manipulation with a single reservoir for both inlet and outlet functions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!