Purpose: Proper placement of infra-acetabular screws is technically demanding; there is a limited safe zone for screw fixation because of the complexity of the bone anatomy around the hip joint and the vulnerability of the major neurovascular bundles in the pelvic cavity. We aimed to present the obturator hook technique as a surgical technique for infra-acetabular screw placement in acetabular and pelvic fractures and report its radiological outcomes.
Methods: Patients treated with infra-acetabular screw placement using the obturator hook technique between January 2015 and August 2020 were enrolled in this study. We collected data on demographics, surgical approach, reduction status, complications, and outcomes. The radiological outcomes of infra-acetabular screw placement based on computed tomography findings were evaluated as follows: success, articular penetration, or out of the bone.
Results: Thirty-five patients underwent infra-acetabular screw placement (26 men, 9 women; mean age, 55 years; range, 27-90 years). One patient underwent bilateral infra-acetabular screw placement; therefore, 36 infra-acetabular screws were inserted in all patients. An ideal placement was achieved with 27 infra-acetabular screws (27/36, 75%). Seven infra-acetabular screws (7/36, 19%) showed articular penetration, and two infra-acetabular screws (2/36, 6%) were placed outside the bone. One patient with articular penetration and mechanical symptoms of the hip joint required screw replacement. No other complications, including obturator nerve and vascular injuries, were observed.
Conclusion: The obturator hook technique could be a favorable and individualized method for infra-acetabular screw placement in patients with acetabular and pelvic fractures.
Level Of Evidence: IV, retrospective descriptive study.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/2309499021996838 | DOI Listing |
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi
September 2024
Department of Orthopaedics, the First Affiliated Hospital of Bengbu Medical University, Anhui Key Laboratory of Tissue Transplantation, Bengbu Anhui, 233004, P. R. China.
Objective: To investigate the application experiences and effectiveness of the infra-acetabular screw (IAS) placement technique in acetabular fracture surgery.
Methods: A clinical data of 34 patients with complex acetabular fractures with anterior and posterior columns separation, who were admitted between January 2019 and October 2023 and treated with IAS fixation, was retrospectively analyzed. There were 23 males and 11 females with an average age of 55.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi
June 2024
Department of Orthopadedic Surgery, the Fourth Medical Center of Chinese PLA General Hospital, Beijing, 100048, P. R. China.
Objective: To investigate the effectiveness of HoloSight Orthopaedic Trauma Surgery Robot-assisted infra-acetabular screw placement for treatment of acetabular fractures.
Methods: The clinical data of 23 patients with acetabular fractures treated with open reduction and internal fixation and infra-acetabular screw placement in two medical centers between June 2022 and October 2023 were retrospectively analyzed. According to the the method of infra-acetabular screw placement, the patients were divided into navigation group (10 cases, using HoloSight Orthopaedic Trauma Surgery Robot-assisted screw placement) and freehand group (13 cases, using traditional X-ray fluoroscopy to guide screw placement).
Injury
June 2024
Department of Orthopedic Surgery, Science of Functional Recovery and Reconstruction, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, 2-5-1 Shikata, Kitaku, Okayama City, Okayama, 700-8558 Japan.
Background: In acetabular fracture surgery, an infra-acetabular screw (IAS) is inserted from the anterior to the posterior column through the infra-acetabular corridor to stabilize both columns. Although the IAS is useful for increasing fixation strength, proper placement requires proficiency and often results in extraosseous screw penetration. The complex anatomy of the infra-acetabular corridor and difficult intraoperative detection of the ideal insertion point and angle make proper placement of the IAS challenging.
View Article and Find Full Text PDFJ Orthop Surg Res
April 2023
Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue No.1277, Wuhan, Hubei, 430022, People's Republic of China.
Background: To compare the biomechanical properties and stability, using a finite element model, of four fixation constructs used for the treatment of anterior column and posterior hemi-transverse (ACPHT) acetabular fractures under two physiological loading conditions (standing and sitting).
Methods: A finite element model simulating ACPHT acetabular fractures was created for four different scenarios: a suprapectineal plate combined with posterior column and infra-acetabular screws (SP-PS-IS); an infrapectineal plate combined with posterior column and infra-acetabular screws (IP-PS-IS); a special infrapectineal quadrilateral surface buttress plate (IQP); and a suprapectineal plate combined with a posterior column plate (SP-PP). Three-dimensional finite element stress analysis was performed on these models with a load of 700 N in standing and sitting positions.
Unfallchirurgie (Heidelb)
January 2024
Klinik und Poliklinik für Unfallchirurgie, Universitätsklinikum Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Deutschland.
Background: The principle of joint-preserving treatment of acetabular fractures is the anatomic reduction of joint-bearing elements and internal osteosynthesis. For stabilization of the anterior and posterior columns against each other, the infra-acetabular screw (IAS) is regularly used in the clinical routine.
Objective: The aim of this study was to compare the position of the IAS in the infra-acetabular corridor after navigated placement and after freehand placement.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!