Analysis of formalin-fixed paraffin-embedded (FFPE) tissue by immunohistochemistry (IHC) is commonplace in clinical and research laboratories. However, reports suggest that IHC results can be compromised by biospecimen preanalytical factors. The National Cancer Institute's Biospecimen Preanalytical Variables Program conducted a systematic study to examine the potential effects of delay to fixation (DTF) and time in fixative (TIF) on IHC using 24 cancer biomarkers. Differences in IHC staining, relative to controls with a DTF of 1 hr, were observed in FFPE kidney tumor specimens after a DTF of ≥2 hr. Reductions in H-score and/or staining intensity were observed for c-MET, p53, PAX2, PAX8, pAKT, and survivin, whereas increases were observed for RCC1, EGFR, and CD10. Prolonged TIF of 72 hr resulted in significantly reduced H-scores of CD44 and c-Met in kidney tumor specimens, compared with controls with 12-hr TIF. An elevated probability of altered staining intensity due to DTF was observed for nine antigens, whereas for prolonged TIF an elevated probability was observed for one antigen. Results reported here and elsewhere across tumor types and antigens support limiting DTF to ≤1 hr when possible and fixing tissues in formalin for 12-24 hr to avoid confounding effects of these preanalytical factors on IHC.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8091543 | PMC |
http://dx.doi.org/10.1369/0022155421995600 | DOI Listing |
J Prev Alzheimers Dis
January 2025
Clinical Memory Research Unit, Clinical Sciences in Malmö, Lund University, Lund, Sweden; Memory Clinic, Skåne University Hospital, Sweden. Electronic address:
As novel, anti-amyloid therapies have become more widely available, access to timely and accurate diagnosis has become integral to ensuring optimal treatment of patients with early-stage Alzheimer's disease (AD). Plasma biomarkers are a promising tool for identifying AD pathology; however, several technical and clinical factors need to be considered prior to their implementation in routine clinical use. Given the rapid pace of advancements in the field and the wide array of available biomarkers and tests, this review aims to summarize these considerations, evaluate available platforms, and discuss the steps needed to bring plasma biomarker testing to the clinic.
View Article and Find Full Text PDFBackground: Except host and environmental factors influencing individual human cytokine responses, pre-analytical handling procedures and detection methods also affect cytokine levels.
Methods: In this study, we used cytometric bead array (CBA) and chemiluminescence (ECL). These two methods were used to test serum and plasma samples from 50 healthy adult volunteers and 50 rheumatoid arthritis (RA) patients' cytokine levels.
Clin Chim Acta
January 2025
Department of Pathology and Laboratory Medicine, University of Pennsylvania Perelman School of Medicine and Children's Hospital of Philadelphia, Philadelphia, PA, United States. Electronic address:
Background: Traditionally, urine analysis of calcium (Ca), magnesium (Mg) and phosphate (Phos) requires acidification of the sample. This study aims to assess the need for acidification and evaluate preanalytical factors that influence the accurate measurement of these analytes in urine.
Results: A total of 107 spot urine samples from patients with a median age of 9 years (95% ≤ 21 years of age, range 5 days to 46 years) were analyzed for Ca (n = 94), Mg (n = 97), and Phos (n = 102) with and without acidification.
Clin Chem Lab Med
January 2025
Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, ON, Canada.
Objectives: Careful consideration of the pre-analytical process for urine examination is essential to avoid errors and support accurate results and decision-making. Our objective was to assess the impact of various pre-analytical factors on urine test strip and quantitative chemistry results, including stability, tube type, fill volume, and centrifugation.
Methods: Residual random urine specimens were identified.
Biochem Med (Zagreb)
February 2025
Department of Medical Biochemistry and Laboratory Medicine, Merkur University Hospital, Zagreb, Croatia.
This case report investigates the occurrence of green discoloration in serum and citrate plasma samples collected from a male adult patient following a multivisceral organ transplant. In collected samples, it was necessary to investigate the influence of sample discoloration on the results of laboratory tests and to determine the appropriate approach to sample management. Hematology, coagulation and blood gas analysis showed no flags, but the biochemical lipemia index was susceptible to positive interference, necessitating dilution of the native sample.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!