Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Indocyanine green (ICG) is a multifunctional dye used in tumor localization, tissue perfusion, and lymph node (LN) mapping during fluorescence-guided laparoscopic colorectal surgery.
Purpose: This study aimed to establish the optimal protocol for preoperative endoscopic submucosal ICG injection to perform fluorescence lymph node mapping (FLNM), along with undisturbed fluorescent tumor localization and ICG angiography during a single surgery.
Methods: Colorectal cancer patients (n = 192) were enrolled from May 2017 to December 2019. Colonoscopic submucosal ICG injection was performed 12 to 18 h before surgery. ICG injection protocols were modified based on the total injected ICG (mg) and tattooing site number. The concentrations of ICG were gradually decreased from the standard dose (2.5 mg/ml) to the minimum dose (0.2 mg/ml). Successful FLNM (FLNM-s) was defined as distinct fluorescent LNs observed under NIR camera. The patient's age, sex, body mass index (BMI), stage, cancer location, obstruction, and laboratory findings were compared between the FLNM-s and failed FLNM (FLNM-f) groups to identify clinical and pathological factors that affect FLNM.
Results: In the ICG dose section of 0.5 to 1 mg, the success rate was highest within all functions including FLNM, fluorescent tumor localization, and ICG angiography. FLNM-s was related to ICG dose (0.5-1 mg), multiple submucosal injections, location of cancer, camera light source, and lower BMI. In the multivariate analysis, camera light source, non-obesity, and multiple injections were independent factors for FLNM-s). The mean total number of harvested LNs was significantly higher in the FLNM-s group than that in the FLNM-f group (p < 0.001). The number of metastatic lymph nodes was comparable between the two groups (p = 0.859).
Conclusions: Preoperative, endoscopic submucosal ICG injection with dose range 0.5 to 1 mg would be optimal protocol for multifunctional ICG applications during fluorescence-guided laparoscopic colorectal surgery.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8758609 | PMC |
http://dx.doi.org/10.1007/s00464-021-08382-5 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!