A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Study of a modified non-contact Hall sensor-based flow transducer using centrifugal and momentum force principle. | LitMetric

Study of a modified non-contact Hall sensor-based flow transducer using centrifugal and momentum force principle.

ISA Trans

Instrumentation Engineering Section, Department of Applied Physics, University of Calcutta, 92, A.P.C. Road, Kolkata 700009, India. Electronic address:

Published: January 2022

The paper describes a modified non-contact Hall sensor based centrifugal and momentum force type flow transducer with simple design, low cost and rugged construction. In this transducer two identical permanent magnets are fixed on the two ends of the common balance lever on which sensing U-tube and dummy U-tube are placed at equal distances from the pivot. The movement of lever ends with variation of flow rate, changes the magnet positions with respect to the two identical Hall sensors fixed at two locations just below the magnets. Thus the outputs of the Hall sensors supplied from a stabilized DC source vary with the variation of flow rate. The difference between these outputs is a DC voltage signal non-linearly related with flow rate.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.isatra.2021.02.026DOI Listing

Publication Analysis

Top Keywords

flow rate
12
modified non-contact
8
non-contact hall
8
flow transducer
8
centrifugal momentum
8
momentum force
8
variation flow
8
hall sensors
8
flow
5
study modified
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!