A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Seasonal variation in indoor concentrations of air pollutants in residential buildings. | LitMetric

Seasonal variation in indoor concentrations of air pollutants in residential buildings.

J Air Waste Manag Assoc

Department of Environmental Sciences, Faculty of Science, Alexandria University, Alexandria, Egypt.

Published: June 2021

Indoor concentrations of PM, PM, CO, and CO were measured in 25 naturally ventilated urban residences during the winter and summer seasons in Alexandria, Egypt. Ambient air samples were also collected simultaneously for comparison to indoor measurements. Furthermore, data for air exchange rates, home characteristics, and indoor activities during sampling were collected. It was found that the average indoor PM, PM, CO, and CO concentrations for all homes in winter were 119.4 ± 30.9 μg/m, 85.2 ± 25.8 μg/m, 1.6 ± 0.8 ppm, and 692.4 ± 144.6 ppm, respectively. During summer, the average indoor levels were 98.8 ± 21.8 μg/m, 67.8 ± 14.9 μg/m, 0.5 ± 0.5 ppm, and 558.2 ± 66.2 ppm, respectively. The results indicate that the indoor daily averages of PM and PM concentrations were higher than the World Health Organization (WHO) guidelines for all selected homes in the two sampling periods. For CO and CO levels, the indoor daily averages for all monitored homes were less than the WHO guideline and the American National Standards Institute/American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (ANSI/ASHRAE) Standard 62.1, respectively. A strong seasonal variability was observed, with air quality being particularly poor in winter. Due to increased ventilation rates in summer, indoor levels of air pollutants were strongly dependent on ambient levels, while in winter the indoor concentrations were more strongly affected by indoor sources due to increased human activities and poor ventilation. In addition, stronger indoor/outdoor correlation of air pollutants' levels was found in summer than in winter probably due to higher ventilation and infiltration in the summer. The study also attempted to understand the potential sources and the various determinants that influence indoor PM, CO, and CO concentrations in the two seasons. The findings can assist policymakers to better understand the indoor air pollution problem and to provide a sound basis for the development of proper national IAQ standards in Egypt.: Personal exposure is considerably influenced by indoor air pollution which increases health risks. Assessment of indoor air quality has become a more significant issue in Egypt as people tend to spend most of their time inside buildings, especially in their homes. Currently, there is a lack of research on residential indoor air quality in Egyptian cities in terms of the spatial and temporal variation which prevents an accurate assessment of the current situation to develop effective mitigation measures and to establish national indoor air quality standards. This article is considered the first research studying the effect of seasonality on indoor concentrations of PM, PM, CO, and CO in urban residences in Alexandria. It also studies the indoor/outdoor relationship of air pollutants' levels and identifies their major sources as well as the various determinants that influence their indoor concentrations.

Download full-text PDF

Source
http://dx.doi.org/10.1080/10962247.2021.1895367DOI Listing

Publication Analysis

Top Keywords

indoor concentrations
28
indoor air
20
indoor
19
air quality
16
air
12
concentrations
8
air pollutants
8
urban residences
8
average indoor
8
μg/m ppm
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!