A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

"IRIS SHELF" TECHNIQUE FOR MANAGEMENT OF POSTERIOR SEGMENT INTRAOCULAR FOREIGN BODIES. | LitMetric

"IRIS SHELF" TECHNIQUE FOR MANAGEMENT OF POSTERIOR SEGMENT INTRAOCULAR FOREIGN BODIES.

Retina

Department of Ophthalmology, Faculty of Medicine, Assiut University, Assiut, Egypt; and.

Published: October 2021

Purpose: To describe "iris shelf" technique for removal of posterior segment intraocular foreign bodies (IOFBs) through a corneal incision combined with phacovitrectomy and to report its outcomes.

Methods: Medical records of patients with posterior segment metallic IOFBs who had combined phacovitrectomy were collected and analyzed. In all patients, the IOFB was placed on the iris surface after forming the anterior chamber with viscoelastic to be extracted through a corneal phacoemulsification incision.

Results: Thirty-three eyes of 33 male patients with a mean age of 31.6 ± 8.3 years were included in the study. The mechanism of injury was hammering in 24 eyes (72.7%) and gunshot in 9 eyes (27.3%). The mean interval between injury and IOFB removal was 14.76 ± 6 days. The mean IOFB volume was 8.5 ± 5.5 mm3, and its longest dimension was 3.45 mm (range, 1-8 mm). The mean preoperative corrected distance visual acuity changed from 20/1,500 (1.79 logarithm of the minimum angle of resolution) to 20/94 (0.67 logarithm of the minimum angle of resolution), postoperatively (P < 0.001). Postoperative complications included retinal detachment (two eyes), proliferative vitreoretinopathy (one eye), epiretinal membrane (one eye), and posterior synechiae (three eyes).

Conclusion: The "iris shelf" technique with phacovitrectomy is a safe and reproducible approach for posterior segment IOFB extraction through a corneal incision with favorable visual and anatomical outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1097/IAE.0000000000003154DOI Listing

Publication Analysis

Top Keywords

posterior segment
16
"iris shelf"
12
shelf" technique
12
segment intraocular
8
intraocular foreign
8
foreign bodies
8
corneal incision
8
combined phacovitrectomy
8
logarithm minimum
8
minimum angle
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!