Objective: Electronic medical records-based alerts have shown mixed results in identifying ED sepsis. Augmenting clinical patient-flagging with automated alert systems may improve sepsis screening. We evaluate the performance of a hybrid alert to identify patients in ED with sepsis or in-hospital secondary outcomes from infection.
Methods: We extracted a dataset of all patients with sepsis during the study period at five participating Western Sydney EDs. We evaluated the hybrid alert's performance for identifying patients with a discharge diagnosis related to infection and modified sequential sepsis-related organ functional assessment (mSOFA) score ≥2 in ED and also compared the alert to rapid bedside screening tools to identify patients with infection for secondary outcomes of all-cause in-hospital death and/or intensive care unit admission.
Results: A total of 118 178 adult patients presented to participating EDs during study period with 1546 patients meeting ED sepsis criteria. The hybrid alert had a sensitivity - 71.2% (95% confidence interval 68.8-73.4), specificity - 96.4% (95% confidence interval 96.3-96.5) for identifying ED sepsis. Clinician flagging identified additional alert-negative 232 ED sepsis and 63 patients with secondary outcomes and 112 alert-positive patients with infection and ED mSOFA score <2 went on to die in hospital.
Conclusion: The hybrid alert performed modestly in identifying ED sepsis and secondary outcomes from infection. Not all infected patients with a secondary outcome were identified by the alert or mSOFA score ≥2 threshold. Augmenting clinical practice with auto-alerts rather than pure automation should be considered as a potential for sepsis alerting until more reliable algorithms are available for safe use in clinical practice.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/1742-6723.13748 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!