A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Beta-Alanine and Tris-(hydroxyl methyl) Aminomethane as Peak Modifiers in the Development of RP-HPLC Methods Using Aceclofenac and Haloperidol Hydrochloride as Exemplar Drugs. | LitMetric

In the present analytical approach, beta-alanine (ALA) and tris-(hydroxyl methyl) aminomethane (TRIS) were investigated as peak modifiers due to their water solubility and their possible peak modifying a property. These reagents were tested for their efficacy on the elution of aceclofenac (ACF) and haloperidol hydrochloride (HLC) from C18 column (250 mm × 4.6 mm, 5 μ) equipped with a photodiode array detector. The test reagents were investigated at 0.25 ± 0.05% concentration with a varying % aqueous composition on elution efficacy of HLC and ACF. The added ALA/TRIS in the mobile phase significantly (P < 0.05) improvised the symmetrical elution of HLC with 3-fold theoretical plates increase (P < 0.05) and 10-fold reduced capacity factor as compared to the control run. For ACF, the shoulder effect observed for ACF peak was eliminated. The optimized mobile phase was a combination of acetonitrile and water containing 0.25% beta-alanine/TRIS (pH 3.5 with ortho-phosphoric acid) at the ratio of 70:30 and 60:40% v/v, respectively, for ACF and HLC. The method was validated as per ICHQ2 guidelines. The column performance was tested for reproducibility in non-peak modifier applications and revealed a null effect on the column, thus these agents are relatively less toxic to HPLC columns.

Download full-text PDF

Source
http://dx.doi.org/10.1093/chromsci/bmab010DOI Listing

Publication Analysis

Top Keywords

tris-hydroxyl methyl
8
methyl aminomethane
8
peak modifiers
8
haloperidol hydrochloride
8
beta-alanine tris-hydroxyl
4
aminomethane peak
4
modifiers development
4
development rp-hplc
4
rp-hplc methods
4
methods aceclofenac
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!