A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Selective and Sensitive Method Development and Validation of 1,1-Dimethyl-3-Hydroxy-Pyrrolidinium Bromide Impurity in Glycopyrrolate Oral Solution by Liquid Chromatography-Tandem Mass Spectroscopy. | LitMetric

Objective: A selective and sensitive liquid chromatography-tandem mass spectrometer (LC-MS/MS) method has been developed for the quantification of 1,1-dimethyl-3-hydroxy-pyrrolidinium bromide impurity in glycopyrrolate oral solution.

Materials And Method: The LC-MS/MS analysis was done on X Bridge HILIC (100 × 4.6 mm, 5 μm) analytical column, and the mobile phase used was10 mM ammonium formate with 0.2% formic acid as mobile phase-A and acetonitrile as mobile phase-B with a gradient programme of 5.0 min. The flow rate used was 1.2 mL/min. Triple quadrupole mass detector coupled to positive electrospray ionization operated in multiple reactions monitoring mode was used for the quantification at m/z 116.10 ± 0.5.

Results: Retention time of impurity was found ~3.2 min. The method was validated in terms of specificity, linearity, accuracy, precision, range, limit of detection, limit of quantitation (LOQ) and robustness. Relative standard deviation (RSD) for system suitability was found 1.3%. Calibration plot was linear over the range of 0.050-2.000 μg/mL. Limit of detection and limit of quantification were found 0.017 and 0.051 μg/mL, respectively. The intra- and inter-day precision RSD was 2.3% and the obtained recovery at LOQ to 200% was in between 86.7 and 107.4%.

Conclusion: The low RSD values and high recoveries of the method confirm the suitability of the method.

Download full-text PDF

Source
http://dx.doi.org/10.1093/chromsci/bmab003DOI Listing

Publication Analysis

Top Keywords

selective sensitive
8
11-dimethyl-3-hydroxy-pyrrolidinium bromide
8
bromide impurity
8
impurity glycopyrrolate
8
glycopyrrolate oral
8
liquid chromatography-tandem
8
chromatography-tandem mass
8
limit detection
8
detection limit
8
method
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!