Background: Fluid challenge test is a widely used method for the detection of fluid responsiveness in acute circulatory failure. However, detection of the patient's response to the fluid challenge requires monitoring of cardiac output which is not feasible in many settings. We investigated whether the changes in the pulse oximetry-derived peripheral perfusion index (PPI), as a non-invasive surrogate of cardiac output, can detect fluid responsiveness using the fluid challenge test or not.

Methods: We prospectively enrolled 58 patients with septic shock on norepinephrine infusion. Fluid challenge test, using 200 mL crystalloid solution, was performed in all study subjects. All patients received an additional 300 mL crystalloid infusion to confirm fluid responsiveness. Velocity time integral (VTI) (using transthoracic echocardiography), and PPI were measured at the baseline, after 200 mL fluid challenge, and after completion of 500 mL crystalloids. Fluid responsiveness was defined by 10% increase in the VTI after completion of the 500 mL. The predictive ability of ∆PPI [Calculated as (PPI after 200 mL - baseline PPI)/baseline PPI] to detect fluid responders was obtained using the receiver operating characteristic curve.

Results: Forty-two patients (74%) were fluid responders; in whom, the mean arterial pressure, the central venous pressure, the VTI, and the PPI increased after fluid administration compared to the baseline values. ∆PPI showed moderate ability to detect fluid responders [area under receiver operating characteristic curve (95% confidence interval) 0.82 (0.70-0.91), sensitivity 76%, specificity 80%, positive predictive value 92%, negative predictive value 54%, cutoff value ≥ 5%]. There was a significant correlation between ∆PPI and ∆VTI induced by the fluid challenge.

Conclusion: ∆PPI showed moderate ability to detect fluid responsiveness in patients with septic shock on norepinephrine infusion. Increased PPI after 200 mL crystalloid challenge can detect fluid responsiveness with a positive predictive value of 92%; however, failure of the PPI to increase does not exclude fluid responsiveness.

Clinical Trial Identifier: NCT03805321. Date of registration: 15 January 2019. Clinical trial registration URL: https://clinicaltrials.gov/ct2/show/NCT03805321?term=ahmed+hasanin&rank=9 .

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00540-021-02908-wDOI Listing

Publication Analysis

Top Keywords

fluid responsiveness
28
detect fluid
24
fluid challenge
20
fluid
18
patients septic
12
septic shock
12
fluid responders
12
pulse oximetry-derived
8
oximetry-derived peripheral
8
peripheral perfusion
8

Similar Publications

[Characteristics of immune response induced by mucosal immunization with recombinant adenovirus of Mycobacterium tuberculosis phosphodiesterase].

Xi Bao Yu Fen Zi Mian Yi Xue Za Zhi

January 2025

Department of Microbiology and Pathogenic Biology, Air Force Military Medical University, Xi'an 710032, China. *Corresponding authors, E-mail:

Objective The prevalence of drug-resistant Mycobacterium tuberculosis (Mtb) strains is exacerbating the global burden of tuberculosis (TB), highlighting the urgent need for new treatment strategies for TB. Methods The recombinant adenovirus vaccine expressing cyclic di-adenosine monophosphate (c-di-AMP) phosphodiesterase B (CnpB) (rAd-CnpB), was administered to normal mice via mucosal immunization, either alone or in combination with drug therapy, to treat Mtb respiratory infections in mice.Enzyme-linked immunosorbent assay (ELISA) was used to detect the levels of antibodies in serum and bronchoalveolar lavage fluid (BALF).

View Article and Find Full Text PDF

Purpose: To investigate the morphologic and functional outcomes of nanosecond subthreshold (ST) laser treatment for patients with chronic central serous chorioretinopathy (CSC).

Methods: In this prospective study, 44 patients were treated with the ST nanosecond laser with a follow-up period of 12 months. All target variables were measured at 1, 3, 6 and 12 months after the first laser treatment.

View Article and Find Full Text PDF

Inhaled ozone induces distinct alterations in pulmonary function in models of acute and episodic exposure in female mice.

Toxicol Sci

January 2025

Department of Pharmacology and Toxicology, Ernest Mario School of Pharmacy, Rutgers University, Piscataway, New Jersey, 08854.

Ozone is an urban air pollutant, known to cause lung injury and altered function. Using established models of acute (0.8 ppm, 3 h) and episodic (1.

View Article and Find Full Text PDF

Motile cilia modulate neuronal and astroglial activity in the zebrafish larval brain.

Cell Rep

January 2025

Department of Clinical and Molecular Medicine, Norwegian University of Science and Technology, Erling Skjalgssons Gate 1, 7491 Trondheim, Norway; Kavli Institute for Systems Neuroscience and Centre for Algorithms in the Cortex, Norwegian University of Science and Technology, Olav Kyrres Gate 9, 7030 Trondheim, Norway. Electronic address:

The brain uses a specialized system to transport cerebrospinal fluid (CSF), consisting of interconnected ventricles lined by motile ciliated ependymal cells. These cells act jointly with CSF secretion and cardiac pressure gradients to regulate CSF dynamics. To date, the link between cilia-mediated CSF flow and brain function is poorly understood.

View Article and Find Full Text PDF

Aim: This study aimed to explore the possible bidirectional interrelations between fructose-induced metabolic syndrome (MS) and apical periodontitis (AP).

Methodology: Twenty-eight male Wistar rats were distributed into four groups (n = 7, per group): Control (C), AP, Fructose Consumption (FRUT) and Fructose Consumption and AP (FRUT+AP). The rats in groups C and AP received filtered water, while those in groups FRUT and FRUT+AP received a 20% fructose solution mixed with water to induce MS.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!