Purpose: To report changes in denture satisfaction and oral health-related quality of life (OHRQoL) in edentulous patients treated with two-implant mandibular overdentures (IODs) over a follow-up of 8 to 10 years.

Materials And Methods: This is a follow-up of a previous study carried out between 1997 and 2005. The patients were originally randomly divided into one group receiving IODs and another group who had their conventional mandibular dentures relined (RCD group). The RCD group was offered and received IODs at the 2-year follow-up. The participants completed a self-administered questionnaire containing demographics, 15 variables related to denture satisfaction, and 20 questions from the Oral Health Impact Profile (OHIP-20). Changes over time were analyzed using multilevel linear models for denture satisfaction and multilevel ordinal regression analyses for OHIP-20 variables. Comparisons between groups were analyzed using Mann-Whitney U test for ordinal and t test for metric data.

Results: Disregarding patients who passed away during follow-up, the 29 responders represented a response rate of 76%. The degree of denture satisfaction and the OHIP-20 scores remained high and stable in the IOD group over the 10-year observation period for all but one variable. The same factors showed only a modest improvement in the RCD group for the first 2 years; however, during the subsequent 8 years of the observation period (after receiving IODs), denture satisfaction and OHIP-20 scores improved to the same level as the original IOD group.

Conclusion: The positive effect on denture satisfaction and OHRQoL of edentulous patients treated with two-implant mandibular overdentures remained unchanged 8 to 10 years after treatment.

Download full-text PDF

Source
http://dx.doi.org/10.11607/ijp.7521DOI Listing

Publication Analysis

Top Keywords

denture satisfaction
28
mandibular overdentures
12
rcd group
12
satisfaction oral
8
oral health-related
8
health-related quality
8
quality life
8
ohrqol edentulous
8
edentulous patients
8
patients treated
8

Similar Publications

Purpose: This study aimed to compare different treatment modalities to correct ill-fitted maxillary complete denture either by the conventional relining method or by scanning the relining impression and digitally construct a new denture regarding patient satisfaction, denture retention, and adaptation.

Materials And Methods: Twelve edentulous patients suffering from loose maxillary complete dentures were selected, dentures' borders and fitting surfaces were prepared, and relining impressions were taken, the impressions were scanned and the STL files were used for CAD/CAM milling ( computer aided designing/ computer aided manufacturing) of new maxillary dentures (Group A), then the relining impression went through the conventional laboratory steps to fabricate (Group B) maxillary dentures. Both groups were evaluated regarding patient satisfaction by a specially designed questionnaire, retention values were measured by a digital force gauge at denture insertion appointment and two weeks later, geomagic software was used to evaluate dentures adaptation to oral tissues.

View Article and Find Full Text PDF

Statement Of Problem: Comprehensive data are needed on the performance of chemically activated, chairside hard reline materials when used with computer-aided design and computer-aided manufacturing (CAD-CAM) milled polymethyl methacrylate (PMMA) denture bases and conventionally processed bases. This lack of data affects decisions regarding the chairside reline material to be used for improving the fit and retention of relined complete dentures.

Purpose: The purpose of this in vitro study was to evaluate and compare the shear bond strength (SBS) of 3 chemically activated, chairside hard reline materials on CAD-CAM milled and conventional heat-polymerized PMMA denture bases.

View Article and Find Full Text PDF

Objectives:  To compare the retention and patient satisfaction of attachment-retained versus clasp-retained removable partial dentures (RPDs) over time and to evaluate the impact of retention force on patient satisfaction.

Materials And Methods:  This study included 107 patients with 130 RPDs at the University Dentistry Clinical Center, Prishtina, Kosovo. Patients were divided into two groups: clasp-retained RPDs ( = 79) and attachment-retained RPDs ( = 51).

View Article and Find Full Text PDF

Purpose: To compare digitally fabricated complete dentures to conventionally fabricated dentures using patient- and clinician-reported outcome measures.

Methods: This review was structured according to PRISMA guidelines with the protocol registered in the PROSPERO database (CRD42024526069). An electronic search of the databases with a defined search strategy was completed within PubMed/MEDLINE and Web of Science from January 2000 to March 2024.

View Article and Find Full Text PDF

Effectiveness of CAD-CAM Milled Versus DMLS Titanium Frameworks for Hybrid Denture Prosthesis: A Narrative Review.

J Funct Biomater

December 2024

Department of Prosthodontics and Restorative Dentistry, College of Dentistry, Majmaah University, Al Majmaah 11952, Saudi Arabia.

This narrative review aimed to evaluate the effectiveness of computer-aided design (CAD), computer-aided manufacturing (CAM) milled, and direct metal laser sintering (DMLS) titanium frameworks in hybrid denture prostheses. A structured PICO analysis and a review of ten publications were used to compare titanium frameworks for hybrid dentures made through milling, DMLS, and CAD-CAM milling. Prosthesis success, bone loss, patient satisfaction, framework fit, and biofilm adhesion were among the outcome indicators.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!