A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Finite element analysis of the influence of the posterior tibial slope on mobile-bearing unicompartmental knee arthroplasty. | LitMetric

Finite element analysis of the influence of the posterior tibial slope on mobile-bearing unicompartmental knee arthroplasty.

Knee

Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea. Electronic address:

Published: March 2021

Background: The most common modes of failure reported in unicompartmental knee arthroplasty (UKA) in its first two decades were wear on the polyethylene (PE) insert, component loosening, and progressive osteoarthritis in the other compartment. The rates of implant failure due to poor component positioning in patients who have undergone UKA have been reported. However, the effect of the posterior tibial slope on the biomechanical behavior of mobile-bearing Oxford medial UKA remains unknown.

Methods: We applied finite element (FE) analysis to evaluate the effects of the posterior tibial slope in mobile-bearing UKA on the contact stresses in the superior and inferior surfaces of PE inserts and articular cartilage as well as the forces exerted on the anterior cruciate ligament (ACL). Seven FE models for posterior tibial slopes of -1°, 1°, 3°, 5°, 7°, 9°, and 11° were developed and analyzed under normal-level walking conditions based on this approach.

Results: The maximum contact stresses on both the superior and inferior surfaces of the PE insert decreased as the posterior tibial slope increased. However, the maximum contact stress on the lateral articular cartilage and the force exerted on the ACL increased as the posterior tibial slope increased.

Conclusions: Increasing the tibial slope led to a reduction in the contact stress on the PE insert. However, a high contact stress on the other compartment and increased ACL force can cause progressive osteoarthritis in the other compartment and failure of the ACL.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.knee.2021.01.004DOI Listing

Publication Analysis

Top Keywords

posterior tibial
24
tibial slope
24
contact stress
12
finite element
8
element analysis
8
slope mobile-bearing
8
unicompartmental knee
8
knee arthroplasty
8
progressive osteoarthritis
8
osteoarthritis compartment
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!