Temporary diverting enterostomy might be the initial step while treating gastrointestinal disorders in infants. According to the level of the stoma, calorie, fluid, and electrolyte imbalance might occur. Totally parenteral nutrition (TPN), parenteral fluid, and electrolyte balancing are the choice of support. Owing to limitations of both, distal refeeding (DR) has been suggested as an alternative. However, in English literature, there is no recommended technique for how DR should apply. This article is aimed at evaluating our innovative DR approach, which was not reported earlier. Between 2015 and 2019, patients on whom DR was performed by a cuffed silicon-based tunneled catheter were obtained. A total of 8 patients aged between 1 day and 7.5 years were included. Dislocation of the catheter and skin erosion were the minor complications that were observed. None of them necessitated TPN and vascular access. Moreover, patients could be discharged and were fully fed orally by their guardian at home, and any problem was observed during survival. Consequently, patients did not necessitate vascular access or TPN. They were all fully fed orally, and DR could be performed without a failure to thrive. Therefore, we believe that tunneled catheter DR is a safe and reliable method in infants. Institutional Review Board at Eskisehir Osmangazi University (Protocol no. 07/01/2020-26).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1089/lap.2020.0320 | DOI Listing |
Int J Med Robot
December 2024
Hepato-Biliary-Pancreatic Surgery Division, Florence, Italy.
Background: Minimally invasive distal pancreatectomy offers recognised benefits over open surgery. Robotic surgery, with its shorter learning curve and technical advancements, presents a promising alternative to laparoscopy in managing pancreatic diseases.
Methods: This study enrolled consecutive patients undergoing distal pancreatectomy between January 2013 and May 2022.
Pediatr Surg Int
November 2024
Department of Surgery, The University of Auckland, Auckland, New Zealand.
Clin Nutr
October 2024
Department of Surgery, The University of Auckland, New Zealand; The Insides Company, New Zealand. Electronic address:
Objectives: Neonatal and pediatric intestinal failure related to enterostomy is an infrequent but burdensome condition associated with substantial morbidity and mortality. This study presents the development and clinical validation of a novel device to resolve these problems, by formalizing a safe and efficient enterostomy chyme reinfusion technique.
Methods: A novel neonatal chyme reinfusion device was designed and manufactured ('The Insides Neo', The Insides Company, New Zealand), prior to validation in a feasibility study in tertiary neonatal intensive care centres.
Pol Przegl Chir
October 2023
Department of General Surgery, Seth GSMC & KEMH, Mumbai, India.
<b><br>Introduction:</b> Stoma surgery, which involves creating a diversion of the small intestine through an abdominal wall opening, poses challenges in managing fluid and electrolyte imbalances. Patients with high proximal stoma often rely on costly and risky parenteral nutrition (PN). Distal enteral tube feeding, a method of delivering nutrition to the small intestine, is intended to improve clinical outcomes and reduce complications.
View Article and Find Full Text PDFContemp Clin Trials Commun
April 2023
Department of Pediatric Surgery, University of Leipzig, Germany.
Background: After enterostomy creation, the distal bowel to the ostomy is excluded from the physiologic passage of stool, nutrient uptake, and growth of this intestinal section. Those infants frequently require long-term parenteral nutrition, continued after enterostomy reversal due to the notable diameter discrepancy of the proximal and distal bowel. Previous studies have shown that mucous fistula refeeding (MFR) results in faster weight gain in infants.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!