Background: Early diagnosis of the novel coronavirus disease of 2019 (COVID-19) in asymptomatic and symptomatic patients is crucial to identify infectious individuals and to help prevent the spread of the virus in the community. Several assays have been developed and are in use in today's clinical practice. These assays vary in their analytical and clinical performance. For an accurate diagnosis, medical professionals must become more familiar with the test's utility to select the most appropriate test. This study aims to evaluate the analytical performance of rapid antigen tests used for the detection of SARS-CoV-2 viral antigen compared to RT-PCR SARS-CoV-2 molecular assay.

Methods: Oropharyngeal swab specimens from five COVID-19 patients were tested by seven rapid antigen tests developed by different IVD companies. RT-PCR to detect specific RNA fragments of SARS-CoV-2 was used as a confirmatory test. The cycle threshold (Ct) value, which often reflects viral load, in these specimens ranged from 15 to 35. For the analytical evaluation, extraction fluid of each antigen kit was spiked with attenuated ATCC virus at different concentrations ranging from 4.6x10/mL to 7.5x10/mL and tested with antigen testing kits.

Results: Out of five confirmed positive SARS-CoV-2 specimens by RT-PCR, only one sample showed a positive result by one of the seven evaluated antigen testing kits. The positive result was observed in the specimen with a Ct value of 15. All other evaluated rapid tests were negative for all five positive specimens. This was further confirmed with the spiking study using ATCC attenuated virus, where extraction fluid of each rapid test was spiked with concentrations ranging from 4.6x10/mL to 7.5x10/mL. None of these spiked specimens showed positive results, indicating very low sensitivity of these antigen kits.

Conclusion: This comparison study shows that rapid antigen tests are less sensitive than RT-PCR tests and are not reliable tests for testing asymptomatic patients, who often carry low viral load. Analytical performance of rapid antigen tests should be thoroughly evaluated before implementing it at clinical decision level.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7886288PMC
http://dx.doi.org/10.2147/IJGM.S297762DOI Listing

Publication Analysis

Top Keywords

rapid antigen
20
antigen tests
16
analytical performance
12
performance rapid
12
antigen
10
detection sars-cov-2
8
viral load
8
extraction fluid
8
concentrations ranging
8
ranging 46x10/ml
8

Similar Publications

Nanobodies (Nbs) hold great potential to replace conventional antibodies in various biomedical applications. However, conventional methods for their discovery can be time-consuming and expensive. We have developed a reliable protein selection strategy that combines magnetic activated cell sorting (MACS)-based screening of yeast surface display (YSD) libraries and functional ligand-binding identification by Tat-based recognition of associating proteins (FLI-TRAP) to isolate antigen-specific Nbs from synthetic libraries.

View Article and Find Full Text PDF

Background: Malaria is a major public health problem in the Central African Republic (CAR). Data on malaria epidemiology are often derived from confirmed cases of symptomatic malaria using passive detection approaches, with very limited knowledge of the extent of subclinical and submicroscopic infections.

Methods: A community-based cross-sectional study was conducted in Bangui, the capital of the CAR, to assess the prevalence of subclinical malaria parasitaemia.

View Article and Find Full Text PDF

Preclinical evaluation and preliminary clinical study of Ga-NODAGA-NM-01 for PET imaging of PD-L1 expression.

Cancer Imaging

January 2025

Department of Nuclear Medicine, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Hongkou District, No. 100, Haining Road, Shanghai, 200080, China.

Background: Programmed cell death 1/programmed death ligand-1 (PD-L1)-based immune checkpoint blockade is an effective treatment approach for non-small-cell lung cancer (NSCLC). However, immunohistochemistry does not accurately or dynamically reflect PD-L1 expression owing to its spatiotemporal heterogeneity. Herein, we assessed the feasibility of using a Ga-labeled anti-PD-L1 nanobody, Ga-NODAGA-NM-01, for PET imaging of PD-L1.

View Article and Find Full Text PDF

T-cell redirecting therapy (TCRT), specifically chimeric antigen receptor T-cell therapy (CAR T-cells) and bispecific T-cell engagers (TCEs) represent a remarkable advance in the treatment of multiple myeloma (MM). There are several products available around the world and several more in development targeting primarily B-cell maturation antigen (BCMA) and G protein-coupled receptor class C group 5 member D (GRPC5D). The relatively rapid availability of multiple immunotherapies brings the necessity to understand how a certain agent may affect the safety and efficacy of a subsequent immunotherapy so MM physicians and patients can aim at optimal sequential use of these therapies.

View Article and Find Full Text PDF

Background: Numerous studies have assessed the risk of SARS-CoV-2 exposure and infection among health care workers during the pandemic. However, far fewer studies have investigated the impact of SARS-CoV-2 on essential workers in other sectors. Moreover, guidance for maintaining a safely operating workplace in sectors outside of health care remains limited.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!