Inversion Recovery Ultrashort TE MR Imaging of Myelin is Significantly Correlated with Disability in Patients with Multiple Sclerosis.

AJNR Am J Neuroradiol

From the Department of Radiology (H.J., Y.-J.M., E.Y.C., S.F., R.R.L., A.F.L., G.M.B., J.D.), University of California San Diego, San Diego, California

Published: May 2021

Background And Purpose: MR imaging has been widely used for the noninvasive evaluation of MS. Although clinical MR imaging sequences are highly effective in showing focal macroscopic tissue abnormalities in the brains of patients with MS, they are not specific to myelin and correlate poorly with disability. We investigated direct imaging of myelin using a 2D adiabatic inversion recovery ultrashort TE sequence to determine its value in assessing disability in MS.

Materials And Methods: The 2D inversion recovery ultrashort TE sequence was evaluated in 14 healthy volunteers and 31 patients with MS. MPRAGE and T2-FLAIR images were acquired for comparison. Advanced Normalization Tools were used to correlate inversion recovery ultrashort TE, MPRAGE, and T2-FLAIR images with disability assessed by the Expanded Disability Status Scale.

Results: Weak correlations were observed between normal-appearing white matter volume ( = -0.03, = .88), lesion load ( = 0.22, = .24), and age ( = 0.14, = .44), and disability. The MPRAGE signal in normal-appearing white matter showed a weak correlation with age ( = -0.10, = .49) and disability ( = -0.19, = .31). The T2-FLAIR signal in normal-appearing white matter showed a weak correlation with age ( = 0.01, = .93) and disability ( = 0.13, = .49). The inversion recovery ultrashort TE signal was significantly negatively correlated with age ( = -0.38, = .009) and disability ( = -0.44; = .01).

Conclusions: Direct imaging of myelin correlates with disability in patients with MS better than indirect imaging of long-T2 water in WM using conventional clinical sequences.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8115368PMC
http://dx.doi.org/10.3174/ajnr.A7006DOI Listing

Publication Analysis

Top Keywords

inversion recovery
20
recovery ultrashort
20
imaging myelin
12
normal-appearing white
12
white matter
12
disability
10
disability patients
8
direct imaging
8
ultrashort sequence
8
mprage t2-flair
8

Similar Publications

Left Ventricular Hemodynamic Forces Changes in Fabry Disease: A Cardiac Magnetic Resonance Study.

J Magn Reson Imaging

January 2025

Department of Cardiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China.

Background: Hemodynamic force (HDF) from cardiac MRI can indicate subclinical myocardial dysfunction, and help identify early cardiac changes in patients with Fabry disease (FD). The hemodynamic change in FD patients remains unclear.

Purpose: To explore HDF changes in FD and the potential of HDF measurements as diagnostic markers indicating early cardiac changes in FD.

View Article and Find Full Text PDF

Image quality assessment and white matter hyperintensity quantification in two accelerated high-resolution 3D FLAIR techniques: Wave-CAIPI and deep learning-based SPACE.

Clin Radiol

December 2024

Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea.

Aim: To compare the image quality obtained using two accelerated high-resolution 3D fluid-attenuated inversion recovery (FLAIR) techniques for the brain-deep learning-reconstruction SPACE (DL-SPACE) and Wave-CAIPI FLAIR.

Materials And Methods: A total of 123 participants who underwent DL-SPACE and Wave-CAIPI FLAIR brain imaging were retrospectively reviewed. In a qualitative analysis, two radiologists rated the quality of each image, including the overall image quality, artifacts, sharpness, fine-structure conspicuity, and lesion conspicuity based on Likert scales.

View Article and Find Full Text PDF

Background And Purpose: The central vein sign (CVS) is a diagnostic imaging biomarker for multiple sclerosis (MS). FLAIR* is a combined MRI contrast that provides high conspicuity for CVS at 3 Tesla (3T), enabling its sensitive and accurate detection in clinical settings. This study evaluated whether CVS conspicuity of 3T FLAIR* is reliable across imaging sites and MRI vendors and whether gadolinium (Gd) contrast increases CVS conspicuity.

View Article and Find Full Text PDF

Purpose: The single reference variable flip angle sequence with a multi-echo stack of stars acquisition (SR-VFA-SoS) simultaneously measures temperature change using proton resonance frequency (PRF) shift and T-based thermometry methods. This work evaluates SR-VFA-SoS thermometry in MR-guided focused ultrasound in an in vivo rabbit model.

Methods: Simultaneous PRF shift thermometry and T-based thermometry were obtained in a New Zealand white rabbit model (n = 7) during MR-guided focused ultrasound surgery using the SR-VFA-SoS sequence at 3 T.

View Article and Find Full Text PDF

Quantitative photoacoustic imaging using known chromophores as fluence marker.

Photoacoustics

February 2025

Erasmus MC, Cardiovascular Institute, Department of Cardiology, Biomedical Engineering, Rotterdam, The Netherlands.

Photoacoustic imaging offers optical contrast images of human tissue at acoustic resolution, making it valuable for diverse clinical applications. However, quantifying tissue composition via optical contrast remains challenging due to the unknown light fluence within the tissue. Here, we propose a method that leverages known chromophores (, arterial blood) to improve the accuracy of quantitative photoacoustic imaging.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!