Background: To compare the difference in central corneal thickness (CCT) measurements in normal eyes between a rotating Scheimpflug camera combined with a Placido-disk corneal topographer (Sirius, CSO, Italy) and ultrasound pachymetry (USP).
Methods: A systematic literature search was conducted for relevant studies published on PubMed, Medline, EMBASE, and the Cochrane Library and ClinicalTrials.gov from inception to August 1st, 2019. Primary outcome measures were CCT measurements between Sirius and USP. A random effects model was used to pool CCT measurements.
Results: A total of twelve studies involving 862 eyes were included in this meta-analysis. The meta-analysis found CCT measurements between Sirius and USP to be statistically significantly different (P < 0.0001). The mean difference between Sirius and USP was -11.26 μm with a 95% confidence interval (CI) (-16.92 μm, -5.60 μm). The heterogeneity was I = 60% (P = 0.004).
Conclusion: CCT measurements with the Sirius Scheimpflug-Placido topographer were statistically significantly lower than USP. However, it may be argued that the mean difference of 11.26 μm is not a clinically significant difference.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7891160 | PMC |
http://dx.doi.org/10.1186/s40662-021-00227-5 | DOI Listing |
Catheter Cardiovasc Interv
January 2025
Cardiology Department, Centro Hospitalar Vila Nova de Gaia/Espinho, Vila Nova de Gaia, Portugal.
Transcatheter aortic valve replacement (TAVR) is a well-established treatment for severe aortic stenosis, especially in patients over 75 or those at high surgical risk. While these prosthetic valves have a lower thrombogenic profile than mechanical heart valves, leaflet thrombosis in transcatheter aortic valves (TAV) occurs in an estimated 5%-40% of cases. Most TAV thromboses are subclinical and can be detected via cardiac computed tomography (CCT), which reveals hypo-attenuating leaflet thickening and reduced leaflet motion in asymptomatic patients without elevated transprosthetic gradients on echocardiography.
View Article and Find Full Text PDFAgeing Res Rev
January 2025
CogT Lab, Department of Psychiatry and Behavioral Sciences, Stanford University. Electronic address:
Computerized cognitive training (CCT) is a frontline therapy to prevent or slow age-related cognitive decline. A prerequisite for CCT research to provide clinically relevant improvements in cognition is to understand effective engagement, i.e.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Physics, Loyola College, Affiliated to the University of Madras, Chennai, 600034, India.
This study involves a novel CuO/CoFe₂O₄/MWCNTs (CCT) nanocomposite, developed by integrating cobalt ferrite (CoFe₂O₄) and copper oxide (CuO) nanoparticles onto multi-walled carbon nanotubes (MWCNTs), for the degradation of tetracycline (TC) under visible light. The photocatalyst was extensively characterized using XRD, HR-SEM, EDX, HR-TEM, UV-Vis, BET, and PL analysis. The synthesized CoFe₂O₄ and CuO nanoparticles exhibited crystallite sizes of 46.
View Article and Find Full Text PDFZhonghua Yan Ke Za Zhi
January 2025
Department of Ophthalmology, Affiliated Hospital of Guangdong Medical University, Zhanjiang524000, China.
To observe the characteristics of ocular biological parameters in children with transfusion-dependent β-thalassemia (TDT) and the effect of iron chelator treatment on them. This was a cross-sectional study. Thirty-two children with TDT (TDT group) and 64 healthy children (control group) who were treated in the Affiliated Hospital of Guangdong Medical University from October 2022 to June 2023 were included.
View Article and Find Full Text PDFClin Ophthalmol
December 2024
Riga Stradins University, Department of Ophthalmology, Riga, Latvia.
Purpose: This study evaluates the discrepancies between ACV measurements obtained from the Heidelberg Anterion and Zeiss IOLMaster 700 and investigates the significance of ACV and other ocular biometry parameters.
Patients And Methods: To investigate intraocular fluid circulation, a robust formula was developed for ACV measurement using the Zeiss IOLMaster 700. A pilot study was conducted to validate this formula, which relied on WTW, CCT, and ACD.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!