Cancer of the penis is an uncommon disease in the western world, but it causes significant morbidity and mortality worldwide. Discussions have tended to centre around issues of local tumor control and the functional status of the penis after treatment. Since November 1982 we have treated localized squamous cell penile cancer (Tis, T1 and T2, Classification UICC, Geneva 1978) with the Nd-YAG laser. Sixteen patients (3Tis, 5T1 and 8T2 tumors) are included in this study with a follow-up of 4 to 36 months (mean 17 months). Eight out of 16 patients were treated with the sapphire probe exclusively, the other eight patients by scalpel excision followed by laser irradiation. No recurrent tumor was observed in 13 patients, one patient developed a recurrence at a non-treated part of the glans penis after 14 months, one patient showed Tis after 5 months near the treated side and in one patient an incomplete laser resection was followed by partial penectomy after 1 month. Sapphire probe laser excision is a safe procedure leading to a good cosmetic aspect with maintenance of the functional integrity of the penis.

Download full-text PDF

Source

Publication Analysis

Top Keywords

sapphire probe
12
probe laser
8
laser
5
penis
5
laser surgery
4
surgery localized
4
localized carcinoma
4
carcinoma penis
4
penis cancer
4
cancer penis
4

Similar Publications

A dual-mode biosensor for microRNA detection based on DNA tetrahedron-gated nanochannels.

Mikrochim Acta

January 2025

Key Laboratory of Synthetic and Natural Functional Molecule, College of Chemistry and Materials Science, Northwest University, Xi'an, 710127, People's Republic of China.

A biosensor based on solid-state nanochannels of anodic aluminum oxide (AAO) membrane for both electrochemical and naked-eye detection of microRNA-31 (MiR-31) is proposed. For this purpose, MoS nanosheets, which possess different adsorption capabilities to single-stranded and double-stranded nucleic acids, are deposited onto the top surface of the AAO membrane. Moreover, multi-functional DNA nanostructure have been designed by linking a G-rich sequence for folding to a G-quadruplex at three vertices and a complementary sequence of MiR-31 at the other one vertex of a DNA tetrahedron.

View Article and Find Full Text PDF

Controlling the structure of polymer solutions near a solid surface is crucial for many industrial processes as it significantly impacts solution flow and influences slip at the interface. To date, only a few techniques have been developed to experimentally investigate this type of interface at the nanometric scale of solid/liquid interactions. In this study, we probe the interface between a smooth sapphire surface and a semidilute polystyrene solution, using neutron reflectivity.

View Article and Find Full Text PDF

Dual single-atom catalysts have attracted considerable research interest due to their higher metal atom loading and more flexible active sites compared to single-atom catalysts (SACs). We pioneered the one-step synthesis of sheets copper-cobalt graphitic carbon nitride dual single-atom (S-Cu/Co-g-C3N4) using folding fan-shaped aluminum foil as a template, and used them as catalysts in the epoxidation of styrene respectively. Through XAFS(X-ray Absorption Fine Structure) and other characterizations, it is found that Cu and Co single atoms are stabilized separately on g-C3N4 via coordination with nitrogen (N), hindered the ordered growth of sheets, and formed more pore structures, which not only increased more catalytically active sites, but also effectively prevented the flakes re-aggregate during the catalytic process.

View Article and Find Full Text PDF

A NIR-II fluorescence probe for tracking oxidative stress in plants induced by metal contaminants.

Anal Methods

December 2024

State Key Laboratory of Luminescent Materials and Devices, Guangdong Provincial Key Laboratory of Luminescence from Molecular Aggregates, College of Materials Science and Engineering, South China University of Technology, Guangzhou 510640, China.

The contamination of some metal ions in soil and water can cause oxidative stress to plants through several mechanisms such as generation of reactive oxygen species, which impair growth, development and productivity of crops. The oxidative stress in plants results in elevation in NO levels which can be adopted as a marker for tracking the stress. Herein we report a new approach for tracking oxidative stress induced by metal ions in plants by using a NIR-II fluorescence probe (Cy-TPE-NH).

View Article and Find Full Text PDF

In this study, a novel organic photophotochemical transistor (OPECT) biosensing platform was proposed for dual-mode detection of CEA. The dual-mode detecting system is achieved benefit from the exceptional photoelectric performance of MIL-53(Fe) -NH@ZnInS (MNZ) and the peroxidase enzyme (POD) activity of ZIF-67/CuCoO (ZIF-67/CuCoO). Ab2- ZIF-67/CuCoO probe was immobilized on a 96-well plate by enzyme-linked immunosorbent assay, which accelerated the oxidation of 3,3,5,5-tetramethylbenzidine (TMB) by hydrogen peroxide and thus successfully realized visual detection of CEA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!