Comparison of the RayStation photon Monte Carlo dose calculation algorithm against measured data under homogeneous and heterogeneous irradiation geometries.

Phys Med

Department of Radiotherapy Physics, Northern Centre for Cancer Care, Freeman Hospital, Freeman Road, Newcastle upon Tyne NE7 7DN, UK.

Published: February 2021

Purpose: This work compares Monte Carlo dose calculations performed using the RayStation treatment planning system against data measured on a Varian Truebeam linear accelerator with 6 MV and 10 MV FFF photon beams.

Methods: The dosimetric performance of the RayStation Monte Carlo calculations was evaluated in a variety of irradiation geometries employing homogeneous and heterogeneous phantoms. Profile and depth dose comparisons against measurement were carried out in relative mode using the gamma index as a quantitative measure of similarity within the central high dose regions.

Results: The results demonstrate that the treatment planning system dose calculation engine agrees with measurement to within 2%/1 mm for more than 95% of the data points in the high dose regions for all test cases. A systematic underestimation was observed at the tail of the profile penumbra and out of field, with mean differences generally <0.5 mm or 1% of curve dose maximum respectively. Out of field agreement varied between evaluated beam models.

Conclusions: The RayStation implementation of photon Monte Carlo dose calculations show good agreement with measured data for the range of scenarios considered in this work and is deemed sufficiently accurate for introduction into clinical use.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejmp.2021.02.002DOI Listing

Publication Analysis

Top Keywords

monte carlo
12
carlo dose
8
dose calculation
8
homogeneous heterogeneous
8
irradiation geometries
8
treatment planning
8
planning system
8
high dose
8
dose
6
comparison raystation
4

Similar Publications

In recent years, power analysis has become widely used in applied sciences, with the increasing importance of the replicability issue. When distribution-free methods, such as partial least squares (PLS)-based approaches, are considered, formulating power analysis is challenging. In this study, we introduce the methodological framework of a new procedure for performing power analysis when PLS-based methods are used.

View Article and Find Full Text PDF

Monte Carlo simulation to optimize polymyxin B dosing regimens for the treatment of Gram-negative bacteremia.

Front Cell Infect Microbiol

March 2025

Department of Pharmacy, Qilu Hospital (Qingdao), Cheeloo College of Medicine, Shandong University, Qingdao, Shandong, China.

Objective: This study aimed to predict and evaluate the efficacy of various polymyxin B dosing regimens for Gram-negative bacteremia using Monte Carlo simulation, with a specific focus on assessing the efficacy in patients receiving continuous renal replacement therapy (CRRT). The goal was to optimize clinical dosing regimens and guide rational polymyxin B use in practice.

Methods: A total of 1,939 Gram-negative bacterial strains were analyzed, collected between April 2019 and December 2021 through the China Bloodstream Gram-negative Pathogens Antimicrobial Resistance and Virulence Surveillance Network (CARVIS-NET).

View Article and Find Full Text PDF

Biodiversity is in rapid decline, but the extent of loss is not well resolved for poorly known groups. We estimate the number of extinctions for Australian non-marine invertebrates since the European colonisation of the continent. Our analyses use a range of approaches, incorporate stated uncertainties and recognise explicit caveats.

View Article and Find Full Text PDF

Based on Cognitive Load Theory, this study developed a moderated mediation model to examine the relationship between English as foreign language (EFL) teachers' air pollution appraisal and negative emotions. Specifically, it hypothesizes that air pollution appraisal significantly increases the mental effort of EFL teachers, which in turn leads to the manifestation of negative emotions. Additionally, the study introduces the concept that the working memory capacity of EFL teachers can negatively moderate the impact of increased mental effort on their emotions, effectively attenuating the overall mediating effect.

View Article and Find Full Text PDF

Objective: To estimate the economic impact of individualized dose optimization guided by antimicrobial therapeutic drug monitoring (TDM) in Spain, compared to no monitoring.

Methods: A cost analysis of antibiotic treatment of critically ill patients, with and without TDM, was performed using a probabilistic Markov model (with second-order Monte Carlo simulations). Three scenarios were analyzed based on three published meta-analyses (Analysis 1: Pai Mangalore, 2022; Analysis 2: Sanz-Codina, 2023; Analysis 3: Takahashi, 2023).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!