Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
In this case study, we evaluate the unique physiological profiles of two world-champion breath-hold divers. At close to current world-record depths, the extreme physiological responses to both exercise and asphyxia during progressive elevations in hydrostatic pressure are profound. As such, these professional athletes must be capable of managing such stress, to maintain performing at the forefront human capacity. In both divers, pulmonary function before and after deep dives to 102 m and 117 m in the open sea was assessed using noninvasive pulmonary gas exchange (indexed via the O deficit, which is analogous to the traditional alveolar to arterial oxygen difference), ultrasound B-line scores, airway resistance, and airway reactance. Hydrostatic-induced lung compression was also quantified via spirometry. Both divers successfully performed their dives. Pulmonary gas exchange efficiency was impaired in both divers at 10 min but had mostly restored within a few hours. Mild hemoptysis was transiently evident immediately following the 117-m dive, whereas both divers experienced nitrogen narcosis. Although B-lines were only elevated in one diver postdive, reductions in airway resistance and reactance occurred in both divers, suggesting that the compressive strain on the structural characteristics of the airways can persist for up to 3.5 h. Marked echocardiographic dyssynchrony was evident in one diver after 10 m of descent, which persisted until resolving at ∼77 m during ascent. In summary, despite the enormous hydrostatic and physiological stress to diving beyond 100 m on a single breath, these data provide valuable insight into the extraordinary capacity of those at the pinnacle of apneic performance. This study shows that world-champion breath-hold divers demonstrate incredible tolerability to extreme levels of hydrostatic-induced lung compression. Immediately following dives to >100 m, there were acute impairments in pulmonary gas exchange efficiency, mild accummulation of extravascular lung fluid, noticable intrathoracic discomfort, and evident nitrogen narcosis, however, within a few hours, these had all mostly resolved.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1152/japplphysiol.00877.2020 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!