A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

FDG PET-CT imaging in head and neck paragangliomas: A centre experience. | LitMetric

FDG PET-CT imaging in head and neck paragangliomas: A centre experience.

Clin Endocrinol (Oxf)

Department of Cancer Imaging, KCL School of Biomedical Engineering and Imaging Sciences, Guy's & St Thomas' Hospitals NHS Foundation Trust, London, UK.

Published: August 2021

Unlabelled: Head and neck paragangliomas (HNPGLs) are rare tumours with ~ 30% genetic mutations, mainly in succinate dehydrogenase (SDHx) genes. The utility of FDG PET-CT in HNPGLs is questioned by recent developments in novel radiotracers. We therefore performed a retrospective study in a single tertiary referral centre to address the utility of FDG PET/CT in HNPGLs.

Methods: Clinical data on genetic testing and follow-up were collected for patients who had FDG PET-CT scans from 2004 to 2016. Receiver operator characteristic (ROC) analysis was used to compare standardized uptake values (SUVs), metabolic tumour volume (MTV) and total lesion glycolysis (TLG) between lesions in patients who had a clinically related event: event (+) and those who did not: event (-). Similarly, we compared PET parameters between SDHx+ patients and a control group with low probability of mutation.

Results: Of 153 HNPGL patients, 73 (29 SDHx+) with 93 FDG-positive lesions were identified: 53.8% of lesions were assessed in a pre-therapeutic setting. In comparison with a reference extracted from clinicoradiological database, FDG PET-CT showed good performance to detect HNPGLs (96.6% accuracy). In this study population, 16 disease progression, 1 recurrence and 1 death were recorded and event (+) patients had lesions with higher SUVmax (p = .03 and p = .02, respectively). Conversely, there were no differences in PET parameters between lesions in SDHx+ patients and controls with low probability of SDHx+ mutations.

Conclusions: FDG PET-CT has clinical utility in HNPGLs, mostly before local treatment. There were no significant differences in PET parameters between SDHx patients and a sporadic HNPGL population. However, regardless of SDHx mutation status, a high SUVmax was associated with more clinical events and prompts to a closer follow-up.

Download full-text PDF

Source
http://dx.doi.org/10.1111/cen.14446DOI Listing

Publication Analysis

Top Keywords

fdg pet-ct
20
pet parameters
12
head neck
8
neck paragangliomas
8
utility fdg
8
event event
8
sdhx+ patients
8
low probability
8
differences pet
8
patients
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!