Background: The Gerbode defect is a rare abnormal communication between the left ventricle (LV) and right atrium (RA). The lesion is either congenital or acquired. Acquired defects are largely iatrogenic or infective in origin. We present two cases of acquired Gerbode defects with similar clinical presentations but very different outcomes.
Case Summaries: Patient 1 A 64-year-old male presented with features of decompensated cardiac failure and a low-grade temperature. Dehiscence of a recently implanted bioprosthetic aortic valve and high-velocity LV to RA jet (Gerbode defect) was found on echocardiography. Blood cultures grew and the diagnosis of infective endocarditis was established. The patient was treated with intravenous antibiotics and the aortic valve and Gerbode defect were successfully surgically repaired.Patient 2 An 81-year-old male presented after being found on the floor at home. On admission, he was clinically septic with evidence of decompensated heart failure. No clear infective focus was initially found. Transthoracic echocardiography revealed severe left ventricular impairment, with a normal bioprosthetic aortic valve. He was treated with intravenous antibiotics, but later deteriorated with evidence of embolic phenomena. Repeat echocardiography revealed a complex infective aortic root lesion with bioprosthetic valve dehiscence and flow demonstrated from the LV to RA. Unfortunately, the patient succumbed to the infection and cardiac complications.
Discussion: The Gerbode defect is a rare but important complication of infective endocarditis and valve surgery. Care needs to be taken to assess for Gerbode defect shunts on echocardiogram, especially in the context of previous cardiac surgery.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7873810 | PMC |
http://dx.doi.org/10.1093/ehjcr/ytaa548 | DOI Listing |
J Cardiothorac Vasc Anesth
December 2024
Department of Cardiothoracic Surgery, National Heart Center, Royal Hospital, Muscat, Oman.
A circular shunt, initially described by Shone et al. in 1962, refers to abnormal blood recirculation through complete intracardiac or intra- and extracardiac communications, bypassing the capillary beds. This pathophysiological condition is most commonly associated with complex congenital heart defects, such as Ebstein's malformation, pulmonary atresia, Gerbode defect, and so on.
View Article and Find Full Text PDFHeliyon
November 2024
Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, 250021, PR China.
Background: In clinical practice, intravascular hemolysis is not common after interventional cardiovascular procedures. Although diagnostic and treatment techniques have developed, with the increasing importance placed on people's own health and the popularity of cardiovascular intervention, there have been occasional reports of hemolysis after different cardiovascular interventions, mainly including cardiac pacemaker implantation, atrial-fibrillation radiofrequency ablation, transcatheter aortic-valve implantation (TAVI), transcatheter mitral valve replacement (TMVR) and percutaneous repair of Gerbode defect and percutaneous coronary intervention (PCI) with Impella. However, so far, there have been no relevant reports on postoperative hemolysis after percutaneous coronary intervention (PCI).
View Article and Find Full Text PDFEur Heart J Case Rep
September 2024
Department of Internal Medicine, Iuliu Hatieganu University of Medicine and Pharmacy, 5th Dept. of Internal Medicine, Medical Clinic No.1, 40006 Cluj-Napoca, Romania.
Future Cardiol
October 2024
Department of Pediatrics, Division of Cardiology, University of Tennessee Health Science Center, Le Bonheur Children's Hospital, Memphis, TN, USA.
The Amplatzer Piccolo Occluder (APO) is approved for patent ductus arteriosus (PDA) occlusion in infants weighing >700 g but could offer versatility to treat other lesions. Retrospective review of children in whom APO was utilized for defects other than PDA between January 2022 and June 2023. The APO was used in nine patients; three for ventricular septal defects, four with coronary fistulas, one for a ventricular pseudoaneurysm and one where APO deployed within a fenestration of a previously placed Amplatzer Septal Occluder.
View Article and Find Full Text PDFAnn Pediatr Cardiol
July 2024
Department of Pediatric Cardiac Intensive Care, NH-Rabindranath Tagore International Institute of Cardiac Sciences, Kolkata, West Bengal, India.
Introduction: The study aims to assess the procedural outcomes and follow-up after transcatheter closure of ventricular septal defects (VSDs) in children utilizing the Konar-MF™ occluder (Lifetech Scientific, Shenzhen, PRC) device.
Materials And Methods: Clinical features, demographic characteristics, and follow-up findings of children undergoing percutaneous VSD device closure were retrospectively analyzed from the medical records.
Results: Fifty-seven patients underwent VSD closure using the Konar-MF occluder between January 2019 and April 2023.