Pacing Clin Electrophysiol
December 2024
Department of Cardiology II - Electrophysiology, University Hospital Münster, Münster, Germany.
Background: Noninferiority of omitting intraoperative defibrillation threshold (DFT) testing has been documented for transvenous implantable cardioverter defibrillators (ICD) whereas data for the subcutaneous-ICD (S-ICD) regarding the need for DFT testing, especially during S-ICD generator replacement, is not available.
Methods: A total of 112 consecutive patients who underwent S-ICD generator replacement and routine testing were included in this retrospective single-center study and analyzed regarding the outcome of intraoperative DFT.
Results: The majority of patients (87.
Cureus
November 2024
Radiology, Kawasaki Municipal Hospital, Kawasaki, JPN.
We experienced a case of a patient with a history of pacemaker implantation who was found to have lung cancer just behind the pacemaker. She was an 80-year-old woman with a history of valve replacement, pacemaker implantation, and sarcoidosis. Computed tomography showed a ground-glass opacity of 1.
View Article and Find Full Text PDFJ Cardiol Cases
December 2024
Department of Cardiovascular Medicine, Osaka University Graduate School of Medicine, Suita, Osaka, Japan.
Unlabelled: New cardiac implantable electronic devices (CIEDs), such as leadless pacemakers and subcutaneous implantable cardioverter defibrillators (S-ICDs), are being used in patients with adult congenital heart disease. The selection of CIEDs often requires careful consideration due to technical challenges posed by a unique heart structure. A 27-year-old man following a surgical tetralogy of Fallot (TOF) repair developed non-sustained ventricular tachycardia, sick sinus syndrome, and complete atrioventricular block.
View Article and Find Full Text PDFJ Arrhythm
December 2024
THEMA Consulting Pty Ltd Milsons Point New South Wales Australia.
Background: Micra™ VR Transcatheter Pacing System (Micra VR) is a single-chamber transcatheter leadless pacemaker. Absence of leads and subcutaneous pocket reduces or completely eliminates the risk of complications associated with the conventional transvenous pacemakers (TVPM). When compared with TVPM, the leadless technology provides a quicker postimplantation recovery and causes less cosmetic concerns/discomfort providing better patient experiences in the long run.
View Article and Find Full Text PDFCirc Arrhythm Electrophysiol
December 2024
Department of Cardiology, Amsterdam UMC Location University of Amsterdam, Heart Center, Amsterdam Cardiovascular Sciences Heart failure and Arrhythmias, the Netherlands (L.R.A.O.N., S.P., L.V.A.B., T.F.B., A.-F.B.E.Q., W.v.d.S., L.S., J.A.d.V., J.G.P.T., N.R.B., J.R.d.G., K.M.K., A.d.W., A.A.M.W., R.E.K.).