Objectives: Patients on venoarterial extracorporeal membrane oxygenation have many risk factors for pulmonary complications in addition to their heart failure. Optimal positive end-expiratory pressure is unknown in these patients. The aim was to evaluate the ability of electrical impedance tomography to help the physician to select the optimal positive end-expiratory pressure in venoarterial extracorporeal membrane oxygenation treated and mechanically ventilated patients during a positive end-expiratory pressure trial.
Design: Observational prospective monocentric.
Setting: University hospital.
Patients: Patients (n = 23) older than 18 years old, on mechanical ventilation and venoarterial extracorporeal membrane oxygenation.
Interventions: A decreasing positive end-expiratory pressure trial (20-5 cm H2O) in increments of 5 cm H2O was performed and monitored by a collection of clinical parameters, ventilatory and ultrasonographic (cardiac and pulmonary) to define an optimal positive end-expiratory pressure according to respiratory criteria (optimal positive end-expiratory pressure selected by physician with respiratory parameters), and then adjusted according to hemodynamic and cardiac tolerances (optimal positive end-expiratory pressure selected by physician with respiratory, hemodynamic, and echocardiographic parameters). At the same time, electrical impedance tomography data (regional distribution of ventilation, compliance, and overdistension collapse) were recorded and analyzed retrospectively to define the optimal positive end-expiratory pressure.
Measurements And Main Results: The median of this optimal positive end-expiratory pressure was 10 cm H2O in our population. Electrical impedance tomography showed that increasing positive end-expiratory pressure promoted overdistention of ventral lung, maximum at positive end-expiratory pressure 20 cm H20 (34% [interquartile range, 24.5-40]). Decreasing positive end-expiratory pressure resulted in collapse of dorsal lung (29% [interquartile range, 21-45.8]). The optimal positive end-expiratory pressure selected by physician with respiratory parameters was not different from the positive end-expiratory pressure chosen by the electrical impedance tomography. However, there is a negative impact of a high level of intrathoracic pressure on hemodynamic and cardiac tolerances.
Conclusions: Our results support that electrical impedance tomography appears predictive to define optimal positive end-expiratory pressure on venoarterial extracorporeal membrane oxygenation, aided by echocardiography to optimize hemodynamic assessment and management.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/CCM.0000000000004892 | DOI Listing |
Crit Care
January 2025
Intensive Care, Erasmus Medical Center, Dr. Molewaterplein 40, 3015 GD, Rotterdam, The Netherlands.
Background: Advanced respiratory monitoring through the measurement of esophageal pressure (Pes) as a surrogate of pleural pressure helps guiding mechanical ventilation in ICU patients. Pes measurement with an esophageal balloon catheter, the current clinical reference standard, needs complex calibrations and a multitude of factors influence its reliability. Solid-state pressure sensors might be able to overcome these limitations.
View Article and Find Full Text PDFJ Vasc Bras
January 2025
Universidade Federal da Paraíba - UFPB, Hospital Universitário Lauro Wanderley - HULW, João Pessoa, PB, Brasil.
Pulmonary arteriovenous malformations (PAVM) are characterized by abnormal pulmonary vessels forming arteriovenous shunts that compromise oxygenation of the blood, causing hypoxemia, and predispose to infections and cerebral ischemia. The patient in this case was a 38-year-old male who presented with tachypnea and dyspnea, cyanosis of extremities, and significant digital clubbing. The patient had structural epilepsy secondary to neurosurgery for a cerebral abscess during childhood.
View Article and Find Full Text PDFIntensive Crit Care Nurs
January 2025
Department of Intensive Care Medicine, Hospital Universitario de La Princesa, Madrid, Spain; Centro de investigación en red CIBERES de enfermedades respiratorias, Instituto de Salud, Carlos III, Madrid, Spain. Electronic address:
Objectives: To analyse the effects on respiratory function, lung volume and the regional distribution of ventilation and perfusion of routine postural repositioning in mechanically ventilated critically ill patients.
Methods: Prospective descriptive physiological study. We evaluated gas-exchange, lung mechanics, and Electrical Impedance Tomography (EIT) determined end-expiratory lung impedance and regional ventilation and perfusion distribution in five body positions: supine-baseline (S1); first lateralisation at 30° (L1); second supine position (S2), second contralateral lateralisation (L2) and third final supine position (S3).
Anesth Analg
January 2025
From the Unit for Anaesthesiological Investigations, Department of Anaesthesiology, Pharmacology, Intensive Care and Emergency Medicine, University of Geneva, Geneva, Switzerland.
Background: The rapid advancement of minimally invasive surgical techniques has made laparoscopy a preferred alternative because it reduces postoperative complications. However, inflating the peritoneum with CO2 causes a cranial shift of the diaphragm decreasing lung volume and impairing gas exchange. Additionally, CO2 absorption increases blood CO2 levels, further complicating mechanical ventilation when the lung function is already compromised.
View Article and Find Full Text PDFShock
January 2025
Department of Anesthesiology, The University of Texas Medical Branch, Galveston, Texas.
Introduction: The understanding of the interaction of closed-loop control of ventilation and oxygenation, specifically fraction of inspired oxygen (FiO2) and positive end-expiratory pressure (PEEP), and fluid resuscitation after burn injury and acute lung injury from smoke inhalation is limited. We compared the effectiveness of FiO2, PEEP, and ventilation adjusted automatically using adaptive support ventilation (ASV) and decision support fluid resuscitation based on urine output in a clinically relevant conscious ovine model of lung injury secondary to combined smoke inhalation and major burn injury.
Methods: Sheep were subjected to burn and smoke inhalation injury under deep anesthesia and analgesia.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!