Semiconductor superlattice secure key distribution (SSL-SKD) has been experimentally demonstrated to be a novel scheme to generate and agree on the identical key in unconditional security just by public channel. The error correction in the information reconciliation procedure is introduced to eliminate the inevitable differences of analog systems in SSL-SKD. Nevertheless, the error correction has been proved to be the performance bottleneck of information reconciliation for high computational complexity. Hence, it determines the final secure key throughput of SSL-SKD. In this paper, different frequently-used error correction codes, including BCH codes, LDPC codes, and Polar codes, are optimized separately to raise the performance, making them usable in practice. Firstly, we perform multi-threading to support multi-codeword decoding for BCH codes and Polar codes and updated value calculation for LDPC codes. Additionally, we construct lookup tables to reduce redundant calculations, such as logarithmic table and antilogarithmic table for finite field computation. Our experimental results reveal that our proposed optimization methods can significantly promote the efficiency of SSL-SKD, and three error correction codes can reach the throughput of Mbps and provide a minimum secure key rate of 99%.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7886916 | PMC |
http://dx.doi.org/10.1038/s41598-021-82684-5 | DOI Listing |
BMC Bioinformatics
January 2025
Auburn University, Auburn, AL, 36849, USA.
Background: Pacific Biosciences (PacBio) circular consensus sequencing (CCS), also known as high fidelity (HiFi) technology, has revolutionized modern genomics by producing long (10 + kb) and highly accurate reads. This is achieved by sequencing circularized DNA molecules multiple times and combining them into a consensus sequence. Currently, the accuracy and quality value estimation provided by HiFi technology are more than sufficient for applications such as genome assembly and germline variant calling.
View Article and Find Full Text PDFClin Transl Oncol
January 2025
Department of Radiation Oncology, HM Hospitales, Madrid, Spain.
Introduction: SRS for the treatment of limited brain metastases (BM) is widely accepted, but there are still limitations in the management of numerous BM. Frameless single-isocenter multitarget SRS is a novel technique that allows for rapid treatment delivery to multiple BM. We report our preliminary clinical, dosimetric, and patient´s shifts outcomes with this technique.
View Article and Find Full Text PDFNature
January 2025
Department of Physics, Durham University, Durham, United Kingdom.
Realizing quantum control and entanglement of particles is crucial for advancing both quantum technologies and fundamental science. Substantial developments in this domain have been achieved in a variety of systems. In this context, ultracold polar molecules offer new and unique opportunities because of their more complex internal structure associated with vibration and rotation, coupled with the existence of long-range interactions.
View Article and Find Full Text PDFNature
January 2025
Department of Brain and Cognitive Sciences and McGovern Institute, MIT, Cambridge, MA, USA.
Hippocampal circuits in the brain enable two distinct cognitive functions: the construction of spatial maps for navigation, and the storage of sequential episodic memories. Although there have been advances in modelling spatial representations in the hippocampus, we lack good models of its role in episodic memory. Here we present a neocortical-entorhinal-hippocampal network model that implements a high-capacity general associative memory, spatial memory and episodic memory.
View Article and Find Full Text PDFSci Rep
January 2025
Space Control and Inertial Technology Research Center, Harbin Institute of Technology, Harbin, 150080, Heilongjiang, China.
The phase-delay error of the circuit system is the primary source of the output error observed in the hemispherical resonator gyroscope (HRG). Additionally, the temperature-dependent nature of the phase-delay error results in a deterioration of the initial calibration parameters, which, in turn, significantly impairs the performance of the gyroscope in its intended application. This paper proposes a self-calibration method to effectively suppress the impact of phase-delay error on the application performance of gyroscopes.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!