A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Validation of the Withings Sleep Analyzer, an under-the-mattress device for the detection of moderate-severe sleep apnea syndrome. | LitMetric

Study Objectives: To assess the diagnostic performance of a nonintrusive device placed under the mattress to detect sleep apnea syndrome.

Methods: One hundred eighteen patients suspected to have obstructive sleep apnea syndrome completed a night at a sleep clinic with a simultaneous polysomnography (PSG) and recording with the Withings Sleep Analyzers. PSG nights were scored twice: first as simple polygraphy, then as PSG.

Results: Average (standard deviation) apnea-hypopnea index from PSG was 31.2 events/h (25.0) and 32.8 events/h (29.9) according to the Withings Sleep Analyzers. The mean absolute error was 9.5 events/h. The sensitivity, specificity, and area under the receiver operating characteristic curve at thresholds of apnea-hypopnea index ≥ 15 events/h were, respectively, sensitivity (Se) = 88.0%, specificity (Sp) = 88.6%, and area under the receiver operating characteristic curve (AUROC) = 0.926. At the threshold of apnea-hypopnea index ≥ 30 events/h, results included Se = 86.0%, Sp = 91.2%, AUROC = 0.954. The average total sleep time from PSG and the Withings Sleep Analyzers was 366.6 (61.2) and 392.4 (67.2) minutes, sleep efficiency was 82.5% (11.6) and 82.6% (11.6), and wake after sleep onset was 62.7 (48.0) and 45.2 (37.3) minutes, respectively.

Conclusions: Withings Sleep Analyzers accurately detect moderate-severe sleep apnea syndrome in patients suspected of sleep apnea syndrome. This simple and automated approach could be of great clinical value given the high prevalence of sleep apnea syndrome in the general population.

Clinical Trial Registration: Registry: ClinicalTrials.gov; Name: Validation of Withings Sleep for the Detection of Sleep Apnea Syndrome; URL: https://clinicaltrials.gov/ct2/show/NCT04234828; Identifier: NCT04234828.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8314651PMC
http://dx.doi.org/10.5664/jcsm.9168DOI Listing

Publication Analysis

Top Keywords

sleep apnea
28
withings sleep
24
apnea syndrome
24
sleep
17
sleep analyzers
16
validation withings
8
moderate-severe sleep
8
patients suspected
8
events/h sensitivity
8
area receiver
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!