Graphene-based hybrid van der Waals structures have emerged as a new class of materials for novel multifunctional applications. In such a vertically-stacked heterostructure, it is expected that its mechanical strength can be tailored by the orientation of the constituent monolayers relative to each other. In this paper, we explore this hypothesis by investigating the orientation dependence of the mechanical properties of graphene/h-BN heterostructures together with that of graphene and h-BN bilayers. The calculated results simulating the pull-out experiment show a noticeable dependence of the (out-of-plane) transverse mechanical response, which is primarily governed by the interlayer strength, on the stacking configurations. The degree of the dependence is directly related to the nature of the interlayer interactions, which change from covalent to covalent polar in going from graphene bilayer to graphene/BN to BN bilayer. In contrast, molecular dynamics simulations mimicking nanoindentation experiments predict that the in-plane mechanical response, which mainly depends on the intra-layer interactions, shows little or no dependence on the stacking-order. The BN monolayer is predicted to fracture before graphene regardless of the stacking pattern or configuration in the graphene/BN heterostructure, affirming the mechanical robustness of graphene. Thus, the graphene-based hybrid structures retain both stiffness and toughness required for a wide range of optoelectromechanical applications.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/1361-6528/abe671 | DOI Listing |
Ann Biomed Eng
December 2024
Department of Mechanical Engineering, The Biorobotics and Biomechanics Lab, University of Maine, 168 College Ave, Orono, ME, 04469, USA.
Purpose: Current gait rehabilitation protocols for older adults typically attempt to effect changes in leg movements, while the role of arm movements is often ignored despite evidence of the neurological coupling of the upper and lower extremities. In the present work, we examine the effectiveness of a novel wearable haptic cueing system that targets arm swing to improve various gait parameters in older adults.
Methods: Twenty participants ( years) were recruited to analyze their gait during normal and fast walking without haptic cueing.
Ergonomics
December 2024
Department of Mechanical Engineering, Politecnico di Milano, Lecco, Italy.
Supine postures are increasingly adopted in medical transport, long-duration flights, and other healthcare environments. This study is aimed to identify the effect of vibration direction and magnitude on the objective and subjective responses of the human body in a supine posture. The transmissibilities to the head, chest, abdomen, and thighs of 12 male subjects were measured with single-axis random vibrations in longitudinal ( axis), lateral ( axis), and vertical ( axis) direction at 0.
View Article and Find Full Text PDFNanomaterials (Basel)
December 2024
College of Mechanical Science and Engineering, Northeast Petroleum University, Daqing 163318, China.
The corrosion resistance of nickel-titanium nitride (Ni/TiN) composites is significantly influenced by the operation parameters during the jet pulse electrodeposition (JPE) process. The effect of current density, jet rate, TiN concentration, and duty cycle impact on the anti-corrosion property of Ni/TiN composites were investigated and optimized using the response surface method (RSM). After the optimization of the operation parameters, the corrosion current of Ni/TiN composites decreased from 9.
View Article and Find Full Text PDFNanomaterials (Basel)
December 2024
Department of Naval Architecture and Ocean Engineering, Hongik University, Jochiwon, Sejong 30016, Republic of Korea.
With the growing demand for wind energy, the development of advanced materials for wind turbine support structures and blades has garnered significant attention in both industry and academia. In previous research, the authors investigated the incorporation of graphene platelets (GPLs) into wind turbine blades, focusing on the structural performance and cost-effectiveness relative to conventional fiberglass composites. These studies successfully demonstrated the potential advantages of GPL reinforcement in improving blade performance and reducing the blade's weight and costs.
View Article and Find Full Text PDFNanomaterials (Basel)
December 2024
Department of Applied Science and Technology, Politecnico di Torino, Corso Duca Degli Abruzzi 24, 10129 Turin, Italy.
In the growing field of personalized medicine, non-invasive wearable devices and sensors are valuable diagnostic tools for the real-time monitoring of physiological and biokinetic signals. Among all the possible multiple (bio)-entities, pH is important in defining health-related biological information, since its variations or alterations can be considered the cause or the effect of disease and disfunction within a biological system. In this work, an innovative (bio)-electrochemical flexible pH sensor was proposed by realizing three electrodes (working, reference, and counter) directly on a polyimide (Kapton) sheet through the implementation of CO laser writing, which locally converts the polymeric sheet into a laser-induced graphene material (LIG electrodes), preserving inherent mechanical flexibility of Kapton.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!