Uncertainty analysis of MR-PET image registration for precision neuro-PET imaging.

Neuroimage

Centre for Medical Image Computing; Department of Medical Physics and Biomedical Engineering, University College London Gower Street WC1E 6BT, London, UK; Amsterdam UMC, Vrije Universiteit Amsterdam, Department of Radiology and Nuclear Medicine, Amsterdam, Netherlands.

Published: May 2021

Accurate regional brain quantitative PET measurements, particularly when using partial volume correction, rely on robust image registration between PET and MR images. We argue here that the precision, and hence the uncertainty, of MR-PET image registration is mainly driven by the registration implementation and the quality of PET images due to their lower resolution and higher noise compared to the structural MR images. We propose a dedicated uncertainty analysis for quantifying the precision of MR-PET registration, centred around the bootstrap resampling of PET list-mode events to generate multiple PET image realisations with different noise (count) levels. The effects of PET image reconstruction parameters, such as the use of attenuation and scatter corrections and different number of iterations, on the precision and accuracy of MR-PET registration were investigated. In addition, the performance of four software packages with their default settings for rigid inter-modality image registration were considered: NiftyReg, Vinci, FSL and SPM. Four distinct PET image distributions made of two early time frames (similar to cortical FDG) and two late frames using two amyloid PET dynamic acquisitions of one amyloid positive and one amyloid negative participants were investigated. For the investigated four PET frames, the biggest impact on the uncertainty was observed between registration software packages (up to 10-fold difference in precision) followed by the reconstruction parameters. On average, the lowest uncertainty for different PET frames and brain regions was observed with SPM and two iterations of fully quantitative image reconstruction. The observed uncertainty for the varying PET count-level (from 5% to 60%) was slightly lower than for the reconstruction parameters. We also observed that the registration uncertainty in quantitative PET analysis depends on amyloid status of the considered PET frames, with increased uncertainty (up to three times) when using post-reconstruction partial volume correction. This analysis is applicable for PET data obtained from either PET/MR or PET/CT scanners.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8204268PMC
http://dx.doi.org/10.1016/j.neuroimage.2021.117821DOI Listing

Publication Analysis

Top Keywords

image registration
16
pet
14
pet image
12
reconstruction parameters
12
pet frames
12
registration
9
uncertainty
8
uncertainty analysis
8
image
8
mr-pet image
8

Similar Publications

Background: Minimizing the duration of mechanical ventilation is one of the most important therapeutic goals during the care of preterm infants at neonatal intensive care units (NICUs). The rate of extubation failure among preterm infants is between 16% and 40% worldwide. Numerous studies have been conducted on the assessment of extubation suitability, the optimal choice of respiratory support around extubation, and the effectiveness of medical interventions.

View Article and Find Full Text PDF

Importance: The optimal configuration of a smoking cessation intervention in a lung cancer screening (LCS) setting has not yet been established.

Objective: To evaluate the efficacy of 3 tobacco treatment strategies of increasing integration and intensity in the LCS setting.

Design, Setting, And Participants: In this randomized clinical trial, LCS-eligible current smokers were randomized into 3 treatments: quitline (QL), QL plus (QL+), or integrated care (IC).

View Article and Find Full Text PDF

Background And Objectives: Brain energy deficiency occurs at the early stage of Huntington disease (HD). Triheptanoin, a drug that targets the Krebs cycle, can restore a normal brain energetic profile in patients with HD. In this study, we aimed at assessing its efficacy on clinical and neuroimaging structural measures in HD.

View Article and Find Full Text PDF

Atrophic acne scars present a significant therapeutic challenge. While subcision with various adjunctive treatments, including fractional CO₂ lasers and polydioxanone (PDO) threads, has been employed for scar remodeling, comparative evidence on their efficacy remains limited. This study aims to compare the clinical efficacy and patient satisfaction between subcision with fractional CO₂ laser and subcision with PDO screw threads in managing atrophic acne scars.

View Article and Find Full Text PDF

Purpose: Obesity and type 2 diabetes (T2DM) are major risk factors for hepatic steatosis. Diet or bariatric surgery can reduce liver volume, fat content, and inflammation. However, little is known about their effects on liver function, as evaluated here using the LiMAx test.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!